Prospective validation of the Barcelona scale for the assessment of mucosal cleanliness during upper gastrointestinal endoscopy

2Citations signalées, ce qui n’est pas une note de qualité
13Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : es. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Some validated scales for assessing upper gastrointestinal (UGI) cleanliness have been developed, though none have been widely implemented. Objectives: To evaluate the association between the presence of clinically significant lesions (CSLs) in the UGI tract and mucosal cleanliness using the Barcelona Scale. The secondary objective includes assessing the safety of water lavage during esophagogastroduodenoscopy (EGD). Design: Multicenter prospective study conducted in 14 hospitals in Spain. Methods: From January 2022 to December 2023, patients undergoing EGD were included. After cleansing, the esophagus, fundus, corpus, antrum, and duodenum were scored from 0 (unassessable due to content) to 2 (fully visualized mucosa), with a maximum score of 10. Results: A total of 641 patients were included, and 3205 segments were assessed: 2594 scored “2,” 604 “1,” and 7 “0.” In 272 patients, 327 CSLs were identified: 93 (14.5%) in the esophagus, 223 (34.8%) in the stomach, and 11 (1.7%) in the duodenum. Only five cases of neoplasia were found, all in segments scored “2” (global score ⩾ 9). The CSL detection rates were 0%, 5.3%, and 11.4% for scores 0, 1, and 2, respectively ( p < 0.001), with a significantly higher rate for score “2” compared to “1” (OR 2.29, 95% CI 1.57–3.34). Besides the degree of cleanliness, several factors were independently associated with CSL detection, including the use of a high-definition endoscope (OR 1.87, 95% CI 1.14–3.23), male sex (OR 1.54, 95% CI 1.1–2.17), and age ⩾58 years (OR 1.54, 95% CI 1.09–2.17). Conclusion: The Barcelona scale may be a valid instrument for assessing the quality of cleanliness during EGD in real clinical practice, as it improves the detection of CSL in the UGI.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Prospective validation of the Barcelona scale for the assessment of mucosal cleanliness during upper gastrointestinal endoscopy
Date Crossref
01/08/2025
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Device Sterilization and DisinfectionColorectal Cancer Screening and DetectionEsophageal Cancer Research and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.