Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Off-axis integrated cavity output spectroscopy (OA-ICOS) is an extremely sensitive technique for measuring trace gas concentrations. Nevertheless, recent research has indicated that when the reflectivity of the mirrors forming the cavity is excessively high, it affects the linearity between the absorption signal and concentration. In this study, the causes and limitations of this phenomenon are discussed based on the Beer–Lambert law and the law of light propagation within the cavity. A new equation is derived to describe the nonlinear relationship between the integral area of absorption spectra and gas concentration. The absorption spectra of CO 2 and CH 4 , measured under different experimental conditions and concentrations, were fitted with Voigt functions to obtain parameters such as peak values and integral areas, which were used to verify the theoretical derivation process and results. The experimental results demonstrate that the relationship between the area of the measured absorption spectra and the gas concentration is consistent with the new formula, with an average fitting correlation coefficient of 0.9998. Meanwhile, the experimental results also demonstrate that the effective optical path length indeed decreases with increasing concentration. Furthermore, the cavity reflectances (99.99644% at 6242.6 cm −1 and 99.99833% at 6046.96 cm −1 ) derived from the fitting coefficient of the new concentration expression closely match the reflectances (99.99727% at 6242.6 cm −1 and 99.99868% at 6046.96 cm −1 ) obtained by applying the classical formula to the spectra of the lowest gas concentration. These experimental results validate the theoretical deduction process and expression. This research provides insights for the theoretical and practical advancements of OA-ICOS, which is significant for advancing high-precision trace gas detection technology.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy
- Date Crossref
- 01/03/2026
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.