Aller au contenu principal
Accès ouvert déclaré 2025 article

Effect of switching from intermittently scanned to real‐time continuous glucose monitoring on glycaemic outcomes in adults with type 1 diabetes: A real‐world, Canadian retrospective study

1Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

AIMS: This study investigated the real-world clinical outcomes of switching from intermittently scanned continuous glucose monitoring (isCGM) to real-time CGM (rtCGM) in adults with type 1 diabetes (T1D) from a large Canadian speciality care population. METHODS: This retrospective observational study examined data from January 1, 2018, through July 31, 2023, in the Canadian LMC Diabetes Registry. The analysis measured 6-12-month change in HbA1c in adults with T1D who switched from isCGM to rtCGM and compared changes to a propensity score-matched isCGM cohort. Changes in number of hypoglycaemic events, CGM metrics, body weight, and total daily dose (TDD) of insulin were also evaluated at 6-12-month follow-up. RESULTS: The full T1D rtCGM switch cohort comprised of 136 adults (mean: age 43 years, diabetes duration 20.9 years, baseline HbA1c 67 mmol/mol [8.2%]). For the full cohort, HbA1c was significantly lower at follow-up compared to baseline (∆-7 mmol/mol [∆-0.6%], p < 0.001). The propensity score-matched subset (n = 84) of these participants had a greater HbA1c reduction compared to the matched isCGM cohort (n = 84; adjusted mean difference, 5 mmol/mol [0.5%]; p = 0.002). The matched rtCGM switch subset had significantly higher time in range 3.9-10.0 mmol/L and lower time above range >10.0 mmol/L, time below range <3.9 mmol/L, and mean glucose compared to the isCGM cohort. There were no significant differences in hypoglycaemic events, body weight, and insulin TDD between the matched cohorts. CONCLUSIONS: This real-world analysis of adults with T1D showed that switching from isCGM to rtCGM use led to significant improvements in HbA1c and CGM metrics.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Effect of switching from intermittently scanned to real‐time continuous glucose monitoring on glycaemic outcomes in adults with type 1 diabetes: A real‐world, Canadian retrospective study
Date Crossref
09/08/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Diabetes Management and ResearchDiabetes and associated disordersDiabetes Treatment and Management

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.