Mesoscale CISS Imaging for the Detection of Dural Defects in Spinal CSF Leaks
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background and Purpose Spontaneous intracranial hypotension (SIH) is most often attributable to cerebrospinal fluid (CSF) leaks from the spinal canal, yet precise localization of dural defects remains challenging. While fat-saturated heavily T2-weighted MR myelography (HT2-MRM) is sensitive to spinal longitudinal extradural CSF collections (SLECs), it does not reliably localize the leak site. This study evaluates a two-stage spine MRI protocol incorporating high resolution, mesoscale 3D constructive interference in steady state (meso-CISS) for targeted CSF leak localization. Materials and Methods Twenty consecutive patients with suspected SIH underwent a standardized total spine MRI protocol, including 3D HT2-MRM for SLEC screening. In cases with positive SLEC or indeterminate findings, meso-CISS was performed for targeted high-resolution leak localization. Results Eight patients (40%) demonstrated SLECs on HT2-MRM, prompting further evaluation with meso-CISS. Dural defects were successfully identified in five patients (1.5-8 mm in size). In one case, meso-CISS delineated intrathecal protrusion of ligamentum flavum calcification, suggesting an underlying defect. Compared with HT2-MRM, meso-CISS provided superior visualization of dural defects, arachnoid scarring, and neo-membrane formation. Two cases were limited by motion or metal artifacts. Conclusion A two-stage spine MRI protocol incorporating HT2-MRM and meso-CISS improves the localization of dural defects in SIH. Meso-CISS enhances visualization of small dural tears and associated pathology, facilitating targeted interventions and potentially reducing reliance on invasive myelography. Further studies are warranted to assess its broader clinical impact.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Mesoscale CISS Imaging for the Detection of Dural Defects in Spinal CSF Leaks
- Date Crossref
- 16/07/2025
- Éditeur
- openRxiv
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.