Aller au contenu principal
Accès ouvert déclaré 2025 article

Experimental investigation of oxygen diffusion in the peak and valley region of minibeam patterns during x‐ray irradiation

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Minibeam radiotherapy has demonstrated its potential to reduce normal tissue toxicity while maintaining tumor control. However, the underlying mechanisms behind this phenomenon remain unknown. Recent theoretical studies suggest a dose surrogate by diffusion of into the valley regions. Purpose The aim of this study is to experimentally investigate oxygen depletion and diffusion upon minibeam (MB) irradiation. Methods A 3D‐printed water phantom with four sensors was developed to enable the real‐time, simultaneous measurement of oxygen concentration in the peak and valley. Water with 0%–11% and 0.1%/5.0% was irradiated with broad beam (BB) and MB characterized by peak and valley widths of 2 mm 2 mm and 0.5 mm 2 mm. The depletion was further compared in other chemical environments. Results The oxygen depletion rates per dose in hypoxic water in the valley regions were found to be 3–7 times higher compared to the peaks or BB. This observation was found to be independent of oxygen concentration above 2 %, indicating oxygen depletion saturation. For MB, diffusion between peaks and valleys was observed. After a certain period, an equilibrium between diffusion and dose rate differences was established. Glutathione and HEPES as a medium increased the depletion further and distinguished MB from BB. Conclusions A novel way of simultaneously measuring oxygen in the peak and valley of the MB dose pattern was introduced. The observed oxygen depletion saturation and diffusion between the peaks and valleys suggest the importance of oxygen in spatially fractionated radiotherapy studies, which is even greater for 5 mM glutathione compared to water.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Experimental investigation of oxygen diffusion in the peak and valley region of minibeam patterns during x‐ray irradiation
Date Crossref
01/08/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Radiotherapy TechniquesRadiation Therapy and DosimetryEffects of Radiation Exposure

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.