Aller au contenu principal
Accès ouvert déclaré 2025 article

Feasibility of intraluminal oxygen delivery after minimally invasive esophagus resection

0Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Introduction: Anastomotic leakage (AL) is a severe complication after esophagectomy. Intraluminal oxygen delivery at the anastomosis site might improve the viability of the tissue and thereby reduce the incidence of AL. We present a feasibility study of intraluminal oxygen delivery after esophagectomy. Methods: Eighteen patients scheduled for robot-assisted minimally invasive esophagectomy with an intrathoracic anastomosis were selected to receive an additional manometry catheter for intraluminal oxygen delivery at the anastomosis site. The primary endpoint was the feasibility of placing the catheter in the correct position and staying in situ for five days postoperatively. Intraluminal pressure was monitored during oxygen delivery at flow rates of 0 (control group), 1, 2, or 4 ml/min. Patients were questioned on the comfort of the catheter. Results: In two patients, intraoperative placement of the catheter was unsuccessful. Two others replaced these patients according to the study protocol. 16 patients were analyzed. In five patients, the catheter was accidentally removed before the end of the study. The primary endpoint was successful in 11/16 patients (69 %). Intraluminal pressure in the 1 ml/min group did not differ from the control group. Intraluminal pressure in the 2 ml/min group increased substantially compared to the control group. Patients reported comfort rates that decreased over time. Conclusion: This study shows that it is feasible to administer intraluminal oxygen in the first five days after esophagectomy and that a flow rate of 1 ml/min is not associated with increased intraluminal pressure. Future studies are required to study the effectiveness of intraluminal oxygen delivery in preventing AL.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Feasibility of intraluminal oxygen delivery after minimally invasive esophagus resection
Date Crossref
01/09/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Esophageal Cancer Research and TreatmentEsophageal and GI PathologyPleural and Pulmonary Diseases

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.