Aller au contenu principal
Accès ouvert déclaré 2025 article

Analytical validation and sequencing coverage studies suggest that performance of a liquid biopsy assay is tumor agnostic (DNA-is-DNA)

1Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Per regulatory and standard requirements (e.g., Clinical & Laboratory Standards Institute (CLSI) guidelines, United States Food and Drug Administration (FDA) correspondence), analytical validation (AV) for each companion diagnostic (CDx) biomarker should be repeated using a clinical sample set for each cancer type listed as an indication in labelling for a CDx. Using data from AV studies and Foundation Medicine (FMI)'s clinical database, we evaluated the hypothesis that analytical performance of the FoundationOne®Liquid CDx (F1LCDx) assay is not impacted by cancer type and that large sets of clinical, tumor-specific samples might not be necessary for analytical validation of specific CDx biomarkers. We retrospectively evaluated all liquid biopsy samples from F1LCDx assay AV studies that were executed between April 2019 and November 2021 and clinical samples processed by F1LCDx between September 2020 and October 2021. For the samples from AV studies, we evaluated the precision and concordance performance by F1LCDx between tumor types; and for the clinical samples, we performed analyses comparing the distribution of coverage between tumor types. A total of 31,247 F1LCDx clinical samples and 579 samples from F1LCDx AV studies with a total of 335 disease ontologies (DOs) were included in this study. For precision: the median absolute pairwise difference of mean reproducibility between any pairs of two tumor types is 0.94% [0.01%-2.63%] and the median absolute pairwise difference of mean repeatability between any pairs of two tumor types is 0.91% [0.03%-2.98%]. For concordance: the median absolute [Formula: see text] between any pairs of two tumor types is 1.39% [0.1%-4.1%] and the median absolute [Formula: see text] between any pairs of two tumor types is 0.05% [0%-1%]. For coverage, a similar distribution was observed between tumor types using F1LCDx clinical samples. Herein, the results based on the extensive cohort of 31,826 liquid biopsy samples sequenced by the F1LCDx assay demonstrated that both analytical assessment of precision and concordance and coverage are comparable among tumor types (i.e., deoxyribonucleic acid (DNA) is DNA). The tumor type that circulating tumor DNA (ctDNA) was derived from is therefore not a vital consideration for AV studies for F1LCDx assay.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analytical validation and sequencing coverage studies suggest that performance of a liquid biopsy assay is tumor agnostic (DNA-is-DNA)
Date Crossref
01/08/2025
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Boston Foundation pays non établi dans la notice
    Organisation à but non lucratif
  • Foundation Medicine pays non établi dans la notice
    Organisation à but non lucratif

Boston Foundation et Foundation Medicine.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cancer Genomics and DiagnosticsRenal cell carcinoma treatmentEpigenetics and DNA Methylation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.