Quantification of Total and Unbound Selinexor Concentrations in Human Plasma by a Fully Validated Liquid Chromatography-Tandem Mass Spectrometry Method
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background/Objectives: Selinexor is a selective nuclear-export inhibitor approved for hematologic malignancies, characterized by extensive plasma protein binding (>95%). However, a validated analytical method to accurately measure the clinically relevant unbound fraction of selinexor in human plasma has not yet been established. This study aimed to develop a fully validated bioanalytical assay for simultaneous quantification of total and unbound selinexor concentrations in human plasma. Methods: We established and fully validated an analytical method based on liquid chromatography–tandem mass spectrometry (LC-MS/MS) capable of quantifying total and unbound selinexor concentrations in human plasma. Unbound selinexor was separated using ultrafiltration, and selinexor was efficiently extracted from 50 μL of plasma by liquid–liquid extraction. Chromatographic separation was achieved on a C18 column using an isocratic mobile phase (0.1% formic acid:methanol, 12:88 v/v) with a relatively short runtime of 2.5 min. Results: Calibration curves showed excellent linearity over a range of 5–2000 ng/mL for total selinexor (r2 ≥ 0.998) and 0.05–20 ng/mL for unbound selinexor (r2 ≥ 0.995). The precision (%CV ≤ 10.35%) and accuracy (92.5–104.3%) for both analytes met the regulatory criteria. This method successfully quantified selinexor in plasma samples from renally impaired patients with multiple myeloma, demonstrating potential inter-individual differences in unbound drug concentrations. Conclusions: This validated bioanalytical assay enables precise clinical pharmacokinetic assessments in a short runtime using a small plasma volume and, thus, assists in individualized dosing of selinexor, particularly for renally impaired patients with altered protein binding.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Quantification of Total and Unbound Selinexor Concentrations in Human Plasma by a Fully Validated Liquid Chromatography-Tandem Mass Spectrometry Method
- Date Crossref
- 16/07/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.