Low- n stability and plasma response to RMP in various STEP scenarios
Rattachement africain : us, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract The low- n ( n is the toroidal mode number) magnetohydrodynamic (MHD) stability and plasma response are numerically investigated for various scenarios designed for STEP, that are relevant for the H-mode pedestal analysis. Control of the edge-localized modes (ELMs) with externally applied resonant magnetic perturbations (RMPs) is considered. Optimization of the ELM control coil current configuration, based on the computed plasma MHD response and well-established figures of merit validated on present-day experiments, finds reasonable robustness of a fixed coil phasing (for a given n -number) to control ELMs in all five STEP plasmas considered. Based on certain semi-empirical criteria, the required coil current to achieve ELM suppression is estimated to be about 10–20 kAt with the n = 1 or 2 RMP configuration and about 100–200 kAt for the n = 4 RMP. Systematic linear stability calculations are used to map out stability windows for the low- n kink-peeling modes, in terms of the ideal-wall location and variation of the edge safety factor q 95 with respect to the target design. The kink-peeling stability boundary is found to be generally sensitive to the q 95 variation, which has implications for achieving the quiescent H-mode regime in STEP. Full toroidal quasilinear initial-value simulations for these STEP plasmas find that generation of the edge-harmonic oscillations (EHOs) depends sensitively on the plasma scenario, the initial linear stability of the kink-peeling modes, the initial plasma toroidal flow and q 95 . In general, it is easier (more robust) to access the EHO-regime for two of the cases considered with smaller plasma volume and higher on-axis safety factor. Finally, quasilinear simulations find robust density pumpout due to applied RMPs in these STEP plasmas, but the effect on the plasma toroidal flow varies among different cases.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Low- <i>n</i> stability and plasma response to RMP in various STEP scenarios
- Date Crossref
- 05/08/2025
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.