Aller au contenu principal
Accès ouvert déclaré 2025 article

CVT-HNet: a fusion model for recognizing perianal fistulizing Crohn’s disease based on CNN and ViT

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Accurate identification of anal fistulas is essential, as it directly impacts the severity of subsequent perianal infections, prognostic indicators, and overall treatment outcomes. Traditional manual recognition methods are inefficient. In response, computer vision methods have been adopted to improve efficiency. Convolutional neural networks(CNNs) are the main basis for detecting anal fistulas in current computer vision techniques. However, these methods often struggle to capture long-range dependencies effectively, which results in inadequate handling of images of anal fistulas. METHODS: This study proposes a new fusion model, CVT-HNet, that integrates MobileNet with vision transformer technology. This design utilizes CNNs to extract local features and Transformers to capture long-range dependencies. In addition, the MobileNetV2 with Coordinate Attention mechanism and encoder modules are optimized to improve the precision of detecting anal fistulas. RESULTS: Comparative experimental results show that CVT-HNet achieves an accuracy of 80.66% with significant robustness. It surpasses both pure Transformer architecture models and other fusion networks. Internal validation results demonstrate the reliability and consistency of CVT-HNet. External validation demonstrates that our model exhibits commendable transportability and generalizability. In visualization analysis, CVT-HNet exhibits a more concentrated focus on the region of interest in images of anal fistulas. Furthermore, the contribution of each CVT-HNet component module is evaluated by ablation experiments. CONCLUSION: The experimental results highlight the superior performance and practicality of CVT-HNet in detecting anal fistulas. By combining local and global information, CVT-HNet demonstrates strong performance. The model not only achieves high accuracy and robustness but also exhibits strong generalizability. This makes it suitable for real-world applications where variability in data is common.These findings emphasize its effectiveness in clinical contexts.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
CVT-HNet: a fusion model for recognizing perianal fistulizing Crohn’s disease based on CNN and ViT
Date Crossref
28/07/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Anorectal Disease Treatments and OutcomesInflammatory Bowel DiseaseColorectal Cancer Screening and Detection

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.