Aller au contenu principal
Accès ouvert déclaré 2025 article

Deep Learning-Powered Super Resolution Reconstruction Improves 2D T2-Weighted Turbo Spin Echo MRI of the Hippocampus

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : ch, fi, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: To assess the performance of 2D T2-weighted (w) Turbo Spin Echo (TSE) MRI reconstructed with a deep learning (DL)-powered super resolution reconstruction (SRR) algorithm combining compressed sensing (CS) denoising and resolution upscaling for high-resolution hippocampal imaging in patients with (epileptic) seizures and suspected hippocampal pathology. Methods: A 2D T2w TSE coronal hippocampal sequence with compressed sense (CS) factor 1 (scan time 270 s) and a CS-accelerated sequence with a CS factor of 3 (scan time 103 s) were acquired in 28 patients. Reconstructions using the SRR algorithm (CS 1-SSR-s and CS 3-SSR-s) were additionally obtained in real time. Two readers graded the images twice, based on several metrics (image quality; artifacts; visualization of anatomical details of the internal hippocampal architecture (HIA); visibility of dentate gyrus/pes hippocampi/fornix/mammillary bodies; delineation of gray and white matter). Results: Inter-readout agreement was almost perfect (Krippendorff’s alpha coefficient = 0.933). Compared to the CS 1 sequence, the CS 3 sequence significantly underperformed in all 11 metrics (p < 0.001-p = 0.04), while the CS 1-SRR-s sequence outperformed in terms of overall image quality and visualization of the left HIA and right pes hippocampi (p < 0.001-p < 0.04) but underperformed in terms of presence of artifacts (p < 0.01). Lastly, relative to the CS 1 sequence, the CS 3-SRR-s sequence was graded worse in terms of presence of artifacts (p < 0.003) but with improved visualization of the right pes hippocampi (p = 0.02). Conclusion: DL-powered SSR demonstrates its capacity to enhance imaging performance by introducing flexibility in T2w hippocampal imaging; it either improves image quality for non-accelerated imaging or preserves acceptable quality in accelerated imaging, with the additional benefit of a reduced scan time.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Deep Learning-Powered Super Resolution Reconstruction Improves 2D T2-Weighted Turbo Spin Echo MRI of the Hippocampus
Date Crossref
23/07/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMedical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.