Aller au contenu principal
Accès ouvert déclaré 2025 article

Women's tolerance of breast propagation-based phase-contrast computed tomography (PB-CT) positioning procedure

2Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : au. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Propagation-based phase-contrast computed tomography (PB-CT) as an advanced experimental imaging modality for breast cancer detection is nearing its world-first clinical trial. Due to the stationary synchrotron X-ray beam, participants must be rotated to capture CT data, yet tolerance to this rotation remains unassessed. METHODS: Participants underwent a simulated PB-CT procedure involving breast cups fitting and bed rotations at 10, 20, and 30° per second (°/s). The 30°/s rotation was repeated under eyes-open, eyes-closed, and breath-held conditions. Comfort was assessed via the Fast Motion Sickness Scale (FMS), State-Trait Anxiety Inventory - State (STAI-S), comfort questionnaire, and debriefing questions. Statistical analysis included Wilcoxon tests (baseline vs. each speed), a Friedman test (across all speeds), and a Kruskal-Wallis test (breath-hold condition). RESULTS: Among 27 female participants (median age-range 30-39; interquartile range (IQR) 30-39, >50), 14 completed the breath-hold condition. FMS scores significantly increased at 20°/s (p = 0.002) and 30°/s (p < 0.001); however, median sickness scores remained low across all speeds and conditions, with a maximum median of 2 out of 20, where 0 represents "no sickness" and 20 "severe sickness." STAI-S scores show no significant changes across speeds and conditions, suggesting that while faster rotations may increase physical discomfort, discomfort is limited, and participants' anxiety remains unaffected. CONCLUSION: Breast PB-CT 3D imaging can be comfortably conducted at rotation speeds relevant to future clinical trials. IMPLICATIONS FOR PRACTICE: As PB-CT nears clinical translation, assessing procedural comfort is essential for developing patient-centered protocols that balance experience and image quality.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Women's tolerance of breast propagation-based phase-contrast computed tomography (PB-CT) positioning procedure
Date Crossref
01/12/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced X-ray Imaging TechniquesDigital Radiography and Breast ImagingMedical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.