Aller au contenu principal
Accès ouvert déclaré 2025 article

Modeling of a population-based input function (PBIF) using the Feng model in dynamic ⁶⁸Ga-DOTATOC whole body PET/CT scans: feasibility of shortened imaging protocols on PET/CT Vision 600 system ®

0Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

This study focuses on modeling a population-based input function (PBIF) in dynamic ⁶⁸Ga-DOTATOC PET/CT exams, with the aim of developing clinically adoptable protocols. The PBIF is derived from an image-derived input function (IDIF), ensuring a non-invasive and standardized approach to tracer kinetic modeling. Patients with well-differentiated neuroendocrine tumors were included from the GAPETNET clinical trial ( n = 37), divided into a PBIF modeling group ( n = 20) and an independent validation group ( n = 17). Dynamic whole-body (dWB) PET/CT imaging was performed using a Vision 600 PET/CT system. A population-based input function (PBIF) was modeled using the Feng approach and scaled to individual patient-specific IDIFs over two different time windows (sPBIF 3 − 7 : 25–55 min, sPBIF 5 − 7 : 40–55 min). The scaled PBIF was normalized to IDIF data from 6 to 55 min post-injection. A full individual patient-specific IDIF using data from 0 to 70 min post-injectionwas used as the reference for AUC and Ki comparisons. IDIFs and scaled PBIFs were compared by assessing the area under the curve (AUC) and radiotracer influx rate (Ki). Linear correlation and Bland-Altman analyses were conducted for AUC and Ki comparisons. Additionally, Mann-Whitney tests were performed to compare Ki values obtained with IDIF and sPBIF in both tumoral lesions and physiological organs. The lowest mean relative AUC bias was observed with sPBIF 3 − 7 , calculated to be 2.7 ± 7.9%, and was slightly higher with sPBIF 5 − 7 (7.35 ± 8.58%). The correlation coefficient (R²) with the sPBIFs was high, with a minimum of 0.95 for the sPBIF 5 − 7 . When analyzing K i metrics, biases tended to be lower with the 40–55 min time window (Mean ± SD bias = 1.61 ± 3.33 for K i max and 1.64 ± 2.96 for K i mean ). No significant differences in K i values was observed with the sPBIFs compared to the IDIF ( p > 0.05), for either tumoral lesion or physiological organs. Our study has demonstrated the feasibility the PBIF approach to estimate tumor or physiological Ki values from a shortened dWB ⁶⁸Ga-DOTATOC PET acquisition, using the Feng model.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Modeling of a population-based input function (PBIF) using the Feng model in dynamic ⁶⁸Ga-DOTATOC whole body PET/CT scans: feasibility of shortened imaging protocols on PET/CT Vision 600 system ®
Date Crossref
17/07/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging Techniques and ApplicationsMRI in cancer diagnosisRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.