Functional Lumen Imaging Probe as Part of Multimodality Assessment of Esophagogastric Junction Opening Is Important in Longitudinal Follow‐Up of Patients With Treated Achalasia
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
ABSTRACT Background Functional lumen imaging probe (FLIP) utility is established in treatment‐naïve achalasia but less clear following lower esophageal sphincter (LES) directed therapy. Methods Achalasia patients with LES directed therapy across three tertiary care centers between 2017 and 2024 with post‐treatment FLIP and timed barium esophagram (TBE) were retrospectively identified. Reduced esophagogastric junction (EGJ) opening was defined by distensibility index (DI) < 2 mm 2 /mmHg and diameter < 12 mm. Abnormal emptying on TBE was defined as column height ≥ 5 cm at 5 min and/or retained tablet. Eckardt scores ≤ 3 defined clinical response. Key Results The study included 222 patients (46% peroral endoscopic myotomy, 46% laparoscopic Heller myotomy, 8% pneumatic dilation) with a median of 1.4 years to post‐treatment TBE/FLIP. Abnormal emptying on TBE was associated with a narrower median EGJ diameter (13.2 vs. 14.8 mm, p = 0.008), a greater frequency of EGJ diameter < 12 mm (36% vs. 21%, p = 0.012), and a smaller change in EGJ diameter (+4.6 vs. +8.6 mm, p = 0.002). Abnormal emptying on TBE occurred more frequently in patients with EGJ DI < 2 mm 2 /mmHg (8.5% vs. 2.6%, p = 0.052), but was not associated with median EGJ DI (4.5 vs. 5.1 mm 2 /mmHg, p = 0.29) nor median change in EGJ DI (+2.9 vs. +3.9 mm 2 /mmHg, p = 0.25). Patients with reduced EGJ DI or EGJ diameter more often had abnormal TBE (37% vs. 22%, p = 0.012). Only the change in DI (+3.8 vs. +1.5 mm 2 /mmHg, p = 0.012) and diameter (+8.2 vs. +1.6 mm, p = 0.002) on FLIP was associated with a clinical response based on Eckardt ≤ 3. Conclusions and Inferences FLIP following achalasia therapy generally correlates with TBE, although discrepant findings are not uncommon. In particular, FLIP EGJ‐diameter has a strong association with esophageal emptying on TBE. Both TBE and FLIP have limited association with clinical response based on Eckardt, with change in DI and diameter on FLIP most strongly associated. Consequently, FLIP as part of multimodal assessment appears useful in the longitudinal follow‐up of treated achalasia.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Functional Lumen Imaging Probe as Part of Multimodality Assessment of Esophagogastric Junction Opening Is Important in Longitudinal Follow‐Up of Patients With Treated Achalasia
- Date Crossref
- 14/07/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.