Aller au contenu principal
2025 article

Functional Lumen Imaging Probe as Part of Multimodality Assessment of Esophagogastric Junction Opening Is Important in Longitudinal Follow‐Up of Patients With Treated Achalasia

3Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

ABSTRACT Background Functional lumen imaging probe (FLIP) utility is established in treatment‐naïve achalasia but less clear following lower esophageal sphincter (LES) directed therapy. Methods Achalasia patients with LES directed therapy across three tertiary care centers between 2017 and 2024 with post‐treatment FLIP and timed barium esophagram (TBE) were retrospectively identified. Reduced esophagogastric junction (EGJ) opening was defined by distensibility index (DI) < 2 mm 2 /mmHg and diameter < 12 mm. Abnormal emptying on TBE was defined as column height ≥ 5 cm at 5 min and/or retained tablet. Eckardt scores ≤ 3 defined clinical response. Key Results The study included 222 patients (46% peroral endoscopic myotomy, 46% laparoscopic Heller myotomy, 8% pneumatic dilation) with a median of 1.4 years to post‐treatment TBE/FLIP. Abnormal emptying on TBE was associated with a narrower median EGJ diameter (13.2 vs. 14.8 mm, p = 0.008), a greater frequency of EGJ diameter < 12 mm (36% vs. 21%, p = 0.012), and a smaller change in EGJ diameter (+4.6 vs. +8.6 mm, p = 0.002). Abnormal emptying on TBE occurred more frequently in patients with EGJ DI < 2 mm 2 /mmHg (8.5% vs. 2.6%, p = 0.052), but was not associated with median EGJ DI (4.5 vs. 5.1 mm 2 /mmHg, p = 0.29) nor median change in EGJ DI (+2.9 vs. +3.9 mm 2 /mmHg, p = 0.25). Patients with reduced EGJ DI or EGJ diameter more often had abnormal TBE (37% vs. 22%, p = 0.012). Only the change in DI (+3.8 vs. +1.5 mm 2 /mmHg, p = 0.012) and diameter (+8.2 vs. +1.6 mm, p = 0.002) on FLIP was associated with a clinical response based on Eckardt ≤ 3. Conclusions and Inferences FLIP following achalasia therapy generally correlates with TBE, although discrepant findings are not uncommon. In particular, FLIP EGJ‐diameter has a strong association with esophageal emptying on TBE. Both TBE and FLIP have limited association with clinical response based on Eckardt, with change in DI and diameter on FLIP most strongly associated. Consequently, FLIP as part of multimodal assessment appears useful in the longitudinal follow‐up of treated achalasia.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Functional Lumen Imaging Probe as Part of Multimodality Assessment of Esophagogastric Junction Opening Is Important in Longitudinal Follow‐Up of Patients With Treated Achalasia
Date Crossref
14/07/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Gastroesophageal reflux and treatmentsDysphagia Assessment and ManagementEsophageal and GI Pathology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.