Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluating Cardiac Impairment From Abnormal Respiratory Patterns: Insights From a Wireless Radar and Deep Learning Study

1Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : tw, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: Assessing the bidirectional impacts of heart function impairment and sleep-disordered breathing remains underexplored. Thus, this study analyzed respiratory patterns from a wireless radar framework to explore their associations with echocardiographic (2D-echo) measurements. METHODS: Background details, 2D-echo parameters, and biochemical data were collected from patients in a cardiology ward in northern Taiwan. Their radar-based respiratory patterns from the night before and the night of the 2D-echo were obtained, averaged, and used to derive indices such as the respiratory disturbance index (RDI) and periodic breathing (PB) cycle length, representing overall respiratory patterns. Next, retrieved data were grouped based on a 50% left ventricular ejection fraction (LVEF) threshold and analyzed using mean comparisons and regression models to explore relationships. RESULTS: Patients with an LVEF of [Formula: see text]% demonstrated significantly reduced total sleep time, higher RDI, and longer PB cycles compared to those with LVEF >50%. Each 1-event/h increase in the RDI reduced the LVEF by 0.22% (95% confidence interval [CI]: -0.41% to -0.03%, p <0.05), and each 1-s increase in the PB cycle length was associated with a 0.21% LVEF reduction (95% CI: -0.35% to -0.07%). Increases in RDI and PB cycle length were associated with a heightened risk of LVEF declining to [Formula: see text]% from >50%. Subgroup analysis revealed that the PB cycle length was associated with elevated N-terminal-prohormone-brain-natriuretic-peptide (NT-proBNP) levels. CONCLUSIONS: This study demonstrates that a wireless radar framework combined with deep learning can effectively monitor respiratory patterns that are associated with cardiac function. Its contactless nature may support continuous cardiac function assessments. CLINICAL IMPACT: This study highlights the effectiveness of a wireless radar and deep learning framework for monitoring respiratory patterns that are associated with cardiac function (e.g., LVEF), underscoring its potential for long-term cardiac and sleep-disorder management.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluating Cardiac Impairment From Abnormal Respiratory Patterns: Insights From a Wireless Radar and Deep Learning Study
Date Crossref
01/01/2025
Éditeur
Institute of Electrical and Electronics Engineers (IEEE)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Non-Invasive Vital Sign MonitoringObstructive Sleep Apnea ResearchHeart Rate Variability and Autonomic Control

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.