Aller au contenu principal
2025 article

Study on the Application of Refined Management of Foreign Medical Devices and Implants in Infection Control of Orthopedic Implant Surgery

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objective: To analyze the application effect of refined management of foreign medical devices and implants in infection control of orthopedic implant surgery. Methods: 252 patients who underwent orthopedic implant surgery in a hospital from May 2023 to April 2024 were selected and grouped according to the time node of the introduction of the refined management method. 126 patients before the introduction of the refined management method were included in the control group, and the surgical operation was completed by 20 doctors, with a total of 1,204 pieces of medical devices and implants. The 126 patients after the introduction of the refined management method were included in the observation group, and the surgical operations were performed by 21 doctors, using a total of 1,207 medical devices and implants. The two groups were compared in terms of the qualification rate of foreign medical devices and implants, satisfaction with their use, and the rate of infection of surgical incisions in the hospital. Results: The qualified rate of foreign medical devices and implants in the observation group was 96.93%, which was significantly higher than that of 83.97% in the control group (P < 0.05). Satisfaction scores for the observation group in the dimensions of the quality of foreign medical device and implant items, device distribution, timeliness of supply, and improvement of the problem were respectively 85.27 ± 6.78, 86.69 ± 6.73, 85.92 ± 6.47, 86.79 ± 5.83, which were significantly higher than the control group’s 80.42 ± 6.26, 82.24 ± 6.29, 81.19 ± 5.83, 82.14 ± 5.72, and the difference was statistically significant (P < 0.05); the rate of nosocomial surgical incision infection in the observation group was 0.79%, which was significantly lower than that of the control group (6.34%) (P < 0.05). Conclusion: The application of refined management in the infection control of orthopedic implant surgery can obtain ideal results, significantly reducing the risk of nosocomial incision infection and further improving the qualification rate of foreign medical devices and implants, and ultimately, obtaining a higher degree of satisfaction with the use.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Study on the Application of Refined Management of Foreign Medical Devices and Implants in Infection Control of Orthopedic Implant Surgery
Date Crossref
11/07/2025
Éditeur
Bio-Byword Scientific Publishing, Pty. Ltd.
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Shanxi Medical University pays non établi dans la notice
    Université ou école supérieure
  • Shaanxi Provincial People's Hospital pays non établi dans la notice
    Établissement de santé
  • Shanxi Provincial People’s Hospital pays non établi dans la notice
    Établissement de santé

Shanxi Medical University, Shaanxi Provincial People's Hospital et Shanxi Provincial People’s Hospital.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Research and TreatmentsEducational Reforms and Innovations

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.