Aller au contenu principal
Accès ouvert déclaré 2025 article

Anastomotic leakage following robot-assisted minimally invasive esophagectomy (RAMIE): which anastomosis should be preferred?

6Citations signalées — pas une note de qualité
39Institutions déclarées
10Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: The optimal technique for intrathoracic esophagogastric anastomosis in esophagectomy remains undetermined. This study evaluates different anastomotic techniques in robot-assisted minimally invasive esophagectomy (RAMIE) and their impact on anastomotic leakage rates. MATERIALS AND METHODS: This observational, retrospective, comparative cohort study analyzed data obtained from the Upper GI International Robotic Association (UGIRA) Esophageal Registry. All consecutive patients with a histologically proven esophageal malignancy who underwent RAMIE with intrathoracic esophagogastrostomy were included. The anastomotic technique was performed based on the clinical judgement and expertise of each individual surgeon. For comparison, the four most common techniques were included: circular end-to-side, linear side-to-side, handsewn end-to-side, and handsewn end-to-end. The primary endpoint of this study was the occurrence of anastomotic leakage, defined by the Esophagectomy Complications Consensus Group as a full-thickness gastrointestinal defect involving the esophagus, anastomosis, staple line, or conduit, regardless of its presentation or method of identification. RESULTS: Between 2016 and September 2023, 1518 patients were included. Univariable analysis demonstrated that the linear stapled side-to-side anastomosis was associated with the lowest anastomotic leakage rate (14.0%), while the handsewn end-to-end anastomosis had the highest (32.8%) (p < 0.001). The anastomotic leakage rates for circular end-to-side and handsewn end-to-side anastomoses were 19.4% and 26.9%, respectively. Multivariable analysis confirmed that anastomotic technique was independently associated with anastomotic leakage. Specifically, handsewn anastomoses were associated with a higher risk of anastomotic leakage for both end-to-side (OR 1.675, 95% CI 1.195-2.348, p = 0.003) and end-to-end (OR 2.181, 95% CI 1.403-3.390, p < 0.001) techniques compared to circular end-to-side anastomoses. CONCLUSIONS: In RAMIE, linear side-to-side and circular end-to-side stapled anastomoses are associated with lower anastomotic leakage rates compared to handsewn techniques. While acknowledging the multifactorial complexity of anastomotic leakage, these findings favor the use of mechanical stapling in clinical practice.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Anastomotic leakage following robot-assisted minimally invasive esophagectomy (RAMIE): which anastomosis should be preferred?
Date Crossref
10/07/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Esophageal Cancer Research and TreatmentEsophageal and GI PathologyColorectal Cancer Surgical Treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.