VIVA Stent Preclinical Evaluation in Swine: A Novel Cerebral Venous Stent with a Unique Delivery System
Rattachement africain : il. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Venous sinus stenting is a promising treatment for intracranial venous disorders, such as idiopathic intracranial hypertension and pulsatile tinnitus, associated with transverse sinus stenosis. The VIVA Stent System (VSS) is a novel self-expanding braided venous stent designed to navigate tortuous cerebral venous anatomy. This preclinical study assessed the safety, thrombogenicity, and performance of the VSS in a swine model. Methods: Fifteen swine underwent bilateral internal mammary vein stenting with either the VSS (n = 9) or the PRECISE® PRO RX stent (n = 6, reference). Fluoroscopy and thrombogenicity assessments were conducted on the day of stenting, clinical pathology analysis was carried out throughout the in-life phase, and CT Venography was performed before sacrifice. Animals were sacrificed at 30 ± 3 or 180 ± 11 days post-stenting for necropsy and histological evaluation. Results: Fluoroscopic angiography confirmed the successful VSS deployment with complete venous wall apposition and no vessel damage. The VSS achieved the highest scores on a four-point Likert scale for most performance parameters. No thrombus formation was observed on either delivery system. CT Venography confirmed vessel patency, no stent migration, and complete stent integrity. Histopathology showed a mild, expected foreign body reaction at 30 days, which resolved by 180 days, indicating normal healing progression. Both stents showed increased luminal diameter and decreased wall thickness at 180 days, suggesting vessel recovery. No adverse reactions were observed in non-target organs. Conclusions: The VSS exhibited favorable safety, procedural performance, and thromboresistance in a swine model, supporting its potential clinical use for treating transverse sinus stenosis and related conditions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- VIVA Stent Preclinical Evaluation in Swine: A Novel Cerebral Venous Stent with a Unique Delivery System
- Date Crossref
- 03/07/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.