Aller au contenu principal
Accès ouvert déclaré 2025 article

A Radiogenomic Deep Ensemble Learning Model for Identifying Radionecrosis Following Brain Metastases (BM) Stereotactic Radiosurgery in Patients With Non-small Cell Lung Cancer BM

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose Stereotactic radiosurgery (SRS) is widely used for brain metastases (BM), but the risk of radionecrosis poses a challenge in post-SRS management. Given the lack of noninvasive imaging methods for distinguishing radionecrosis from recurrence, we aimed to design a deep ensemble learning model that integrates patient clinical features and genomic profiles to identify radionecrosis in patients with BM with post-SRS radiographic progression. Methods and Materials We studied 90 BMs from 62 patients with non-small cell lung cancer, with 27 biopsy-confirmed post-SRS local recurrences. Clinical features and molecular features were collected. A deep neural network (DNN) was trained for radionecrosis/recurrence prediction using the 3-month post-SRS T1+c magnetic resonance imaging. Preceding the binary prediction output, latent variables were extracted as 1024 deep features. An ensemble learning model was then developed, comprising 2 submodels that fused deep features with clinical (" D+C" ) or genomic (" D+G" ) features. We employed our positional encoding method to optimally fuse the low-dimensional clinical/genomic features with the high-dimensional image features. The postfusion feature in each submodel yielded a logit result after traversing fully connected layers. The ensemble's final output was the synthesized result of these 2 submodels' logits via logistic regression. Model training employed an 8:2 train/test split, and 10 model versions were developed for robustness evaluation. Performance metrics were compared against image-only DNN model and " D+C" and " D+G" submodels. Results The deep ensemble model showed satisfactory performance on the test set, with the area under the receiver operating characteristic curve (ROC AUC ) = 0.91 ± 0.04, sensitivity=0.87 ± 0.16, specificity=0.86 ± 0.08, and accuracy=0.87 ± 0.04. This significantly outperformed the image-only DNN result (ROC AUC = 0.71 ± 0.05, sensitivity=0.66 ± 0.32). Higher average performance was also observed compared to the "D+C" result (ROC AUC = 0.82 ± 0.03, sensitivity=0.67 ± 0.17) and "D+G" result (ROC AUC = 0.83 ± 0.02, sensitivity=0.76 ± 0.22). Conclusions The deep ensemble model achieved the best performance among the models evaluated in this study for distinguishing BM radionecrosis from recurrence using 3-month post-SRS T1+c MR images, clinical features, and genomic features. This highlights the potential of artificial intelligence in clinical decision-making for BM management, warranting further investigation into its clinical applications.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Radiogenomic Deep Ensemble Learning Model for Identifying Radionecrosis Following Brain Metastases (BM) Stereotactic Radiosurgery in Patients With Non-small Cell Lung Cancer BM
Date Crossref
01/08/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Brain Metastases and TreatmentLung Cancer Diagnosis and TreatmentRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.