Altered cardiac‐coronary coupling relates to abnormal fractional flow reserve without flow limitation after percutaneous coronary interventions
Rattachement africain : nl, tr, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract A significant proportion of stenoses have an abnormal fractional flow reserve (FFR) after angiographically successful percutaneous coronary intervention (PCI), which is traditionally attributed to differences in coronary flow velocity reserve (CFVR) or hyperemic microvascular resistance (hMR). This study investigated the mechanisms underlying residual low FFR despite good angiographic results and normalized hyperemic stenosis resistance (hSR) using wave‐intensity analysis (WIA), which evaluates phasic characteristics of cardiac‐coronary coupling. Sixty‐three vessels from patients who underwent PCI for stable intermediate stenoses were included. Peri‐PCI characteristics of conventional and WIA parameters were assessed. Ten (16%) vessels exhibited residual low FFR (≤0.8) despite normalized hSR (<0.8), without significant differences in hyperemic flow (velocity) (hAPV), CFVR, or hMR compared with concordant normal FFR‐hSR group (p > 0.05). WIA revealed a significantly slower (peak‐time of backward expansion wave, tBEWpeak = 20% ± 6% vs. 29% ± 17% of expansion period, p = 0.005) and weaker (BEWpeak = 10.1 ± 8.9 vs. 15.8 ± 11.4 10.kW.m‐2.s‐2, p = 0.045) impact of microvascular suction responsible for diastolic coronary filling during hyperemia in the low FFR group, despite comparable pre‐PCI characteristics. Residual low FFR after PCI may reflect altered cardiac‐coronary coupling without limitation of flow or vasodilator capacity when the blunted impact of accelerating wave energy flux with delayed coronary filling fails to sustain distal pressure. The influence of cardiac‐coronary coupling on post‐PCI FFR warrants further investigation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Altered cardiac‐coronary coupling relates to abnormal fractional flow reserve without flow limitation after percutaneous coronary interventions
- Date Crossref
- 30/06/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.