Superiority of black-blood computed tomography over conventional computed tomography angiography in the identification of soft plaques: a prospective study
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Carotid computed tomography angiography (CTA) has limited diagnostic value in evaluating the vulnerability of soft plaques. This study compared conventional CTA and black-blood computed tomography (BBCT) in terms of image quality and the ability to diagnose carotid soft plaques. Methods: Patients who underwent carotid CTA and magnetic resonance (MR) vessel wall examination were included in this prospective study. The image quality of plaques was evaluated through objective evaluation [CT values, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) based on CTA and BBCT] and subjective evaluation. Plaque burden was assessed with the normalized wall index (NWI) in CTA, BBCT, and MR images, as was the remodeling index (RI). The number of soft plaques in CTA, BBCT, and MR images was recorded. The sensitivity, specificity, and accuracy of an NWI higher than 0.56 and an RI higher than 1.0 from CTA and BBCT images in assessing the vulnerability of soft plaques were calculated with MR vessel wall images as a reference standard. Results: A total of 37 patients comprising 53 soft plaques (25 males and 12 females) were analyzed. The average CT values, SNR, and CNR of soft plaques in BBCT were significantly higher compared to those in CTA (BBCT: 65.38±21.34, 16.31±7.69, 6.47±4.97; CTA: 45.58±14.09, 7.16±3.15, 4.45±2.83; all P values <0.05). The image noise in BBCT was significantly lower than that in CTA (BBCT: 10.73±3.75; CTA: 15.52±6.59; P<0.05), while the subjective image score of BBCT (3.04±0.51) was significantly higher than that of CTA (2.32±0.61) (P<0.001). The sensitivity and specificity of an NWI higher than 0.56 with BBCT were 0.98 and 0.86, respectively, which were superior to those with CTA at 0.83 and 0.57, respectively. Meanwhile, the sensitivity and specificity of an RI higher than 1.0 with BBCT were 0.86 and 0.95, respectively, which were superior to those with CTA at 0.71 and 0.85, respectively. The sensitivity and specificity of BBCT in diagnosing vulnerable plaques were 0.90 and 0.93, respectively, while those of CTA were 0.62 and 0.79, respectively. The area under the receiver operating characteristic curve of BBCT for diagnosing vulnerable plaques was 0.91 (95% CI: 0.803-0.973) while that for CTA was 0.70 (95% CI: 0.559-0.819; P<0.001). Conclusions: Compared to conventional CTA, BBCT provides improved image quality and diagnostic performance in assessing carotid soft plaques.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Superiority of black-blood computed tomography over conventional computed tomography angiography in the identification of soft plaques: a prospective study
- Date Crossref
- 01/07/2025
- Éditeur
- AME Publishing Company
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.