Equivalence assessment of weight bearing cone beam CT and multidetector CT through 3D Knee bone modelling
Rattachement africain : au, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Weight-bearing cone beam computed tomography (WB-CBCT, or simply WBCT), which captures high-resolution 3D images in a natural standing position, has gained increasing interest in recent years. This study examines the potential of WBCT as an alternative to multidetector computed tomography (MDCT) for 3D bone modelling. We generated 3D knee joint models from manually annotated WBCT and MDCT scans, performed rigid registration of these models, and assessed their similarity by evaluating the mean difference, standard deviation, and confidence intervals of the aligned models. The mean differences were computed as the average surface distances between corresponding WBCT and MDCT 3D bone models after rigid registration, providing a quantitative measure of their geometric similarity. Validation was conducted using both patient and cadaver scans to assess WBCT's clinical applicability under realistic conditions and its technical reliability with controlled samples. Our findings reveal an average absolute difference of less than 0.35 mm for patient scans and 0.30 mm for cadaveric scans between WBCT and MDCT. The patella demonstrated the smallest mean difference (-0.20 mm to 0.10 mm) and standard deviation (0.28 mm to 0.55 mm) across all scans. These results confirm the comparability of WBCT to MDCT for 3D bone modelling, highlighting WBCT's capacity to deliver appropriate image quality for the clinical assessment of bone joints.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Equivalence assessment of weight bearing cone beam CT and multidetector CT through 3D Knee bone modelling
- Date Crossref
- 01/07/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Monash University pays non établi dans la noticeUniversité ou école supérieure
-
Tennessee Orthopaedic Alliance pays non établi dans la noticeÉtablissement de santé
-
University of Technology Sydney pays non établi dans la noticeUniversité ou école supérieure
-
Curvebeam AI pays non établi dans la noticeInstitution
-
Hip and Knee Clinic pays non établi dans la noticeÉtablissement de santé
Monash University, Tennessee Orthopaedic Alliance et University of Technology Sydney, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.