Comparison of two transient elastography (TE) systems for measuring liver stiffness in clinical practice
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Inter-instrument variations of liver stiffness measure (LSM) by transient elastography might be problematic in clinical practice. LSMs provided by 2 different systems were compared in outpatients with chronic liver disease (CLD). In 777 consecutive asymptomatic outpatients admitted at the Hepatology Unit of Pisa University Hospital the agreement of LSMs measured by FibroScan ® (Echosens, France) and FT9000 (Hisky Medical, China) (LSM Fibroscan /LSM FT9000 ) was tested using Pearson correlation and Bland-Altman analyses (BAA). Delta FT9000-FibroScan ® LSM (LSM-D) variations were analysed according to clinic-pathologic characteristics. ALT/AST/GGT and platelets-counts/portal-vein-caliber/spleen-bipolar-diameter were used as proxies of necro-inflammatory and portal hypertension, respectively. LSM FT9000 and LSM Fibroscan were highly correlated ( r = 0.781, p < 0.001) overall, but agreement varied according to BMI (normal-weight r = 0.841, over-weight r = 0.747, obese r = 0.647, p < 0.001). LSM showed a + 0.52 kPa bias ( p = 0.01) with − 11/12 kPa as 95% Limit of agreement, with higher values measured by LSM FT9000 below 10 kPa and lower values above 20 kPa. In bivariate analysis LSM-D correlated with LSM Fibroscan and AST (β = 0.002, p = 0.001 with significant interaction, p = 0.018) and was associated with spleen-bipolar-diameter (β = 0.033, p = 0.027) and platelets-count (β=-0.008, p = 0.018) with significant interaction with LSM Fibroscan ( p < 0.001). LSM Fibroscan and LSM FT9000 are strongly correlated overall with optimal agreement around 10 kPa but limited at ends of the dynamic range: LSM FT9000 provides higher values below 10 kPa whereas LSM Fibroscan higher values over 20 kPa with different measures distribution. LSM discrepancies associate with anthropometric characteristics, necro-inflammatory activity and portal hypertension proxies. These findings suggest the need of systems specific cut-offs in clinical practice.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparison of two transient elastography (TE) systems for measuring liver stiffness in clinical practice
- Date Crossref
- 01/07/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.