Detection of 5 GHz photons using Al Josephson junctions at 0.7 K
Rattachement africain : ru, de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Detection of 5 GHz photons using Al Josephson junctions at 0.7 K
- Date Crossref
- 27/06/2025
- Éditeur
- Academia.edu Journals
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.