MIMAC-35×35 cm^2: 3D-nuclear recoil tracks for directional Dark Matter detection and neutron spectroscopy
Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract A new micro-tpc has been built with 1792 channels, 896 channels on each X and Y axis based on the MIMAC detection strategy. The first 3D electron and nuclear recoil events were observed at Grenoble in June 2024. The chamber will be the elementary block to build big active detection volumes. The energy threshold is roughly 100 eV. Based on PCB, the first detectors have been constructed at CERN following the design defined by the LPSC. Based on the same design, a new generation of detectors based on Kapton has been produced at the USTC-Hefei (China) and will be tested shortly. The first 3D tracks from a PCB detector are shown with the calibration spectrum obtained by X-rays.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- MIMAC-35×35 cm^2: 3D-nuclear recoil tracks for directional Dark Matter detection and neutron spectroscopy
- Date Crossref
- 01/06/2025
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.