Aller au contenu principal
Accès ouvert déclaré 2025 article

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

5Citations signalées — pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Résumé fourni par la source

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section , which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube
Date Crossref
01/11/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Sujets associés

Radiation Detection and Scintillator TechnologiesParticle Detector Development and PerformanceRadiation Therapy and Dosimetry

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.