A pilot cohort study of a microfluidic-based point-of-care bilirubin measurement system

1Citations signalées — pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

The concentration of bilirubin in blood or serum is useful for assessing liver function as well as monitoring treatment. This study evaluates the clinical performance of a novel point-of-care (PoC) device for the detection of bilirubin in serum. The PoC device incorporates an integrated miniature optoelectronic sensing module and a microfluidic test cartridge. Patients’ serum total bilirubin concentrations, ranging from 2 ​μmol/L to 480 ​μmol/L, were measured using the PoC device and the standard laboratory method ( n =20). Bland-Altman analysis and regression analysis using Passing-Bablok method were used to benchmark the PoC device against the standard laboratory measurements. The diagnostic capability of the PoC device in categorising the serum samples within clinically relevant bilirubin concentration thresholds of 200, 300, and 450 ​μmol/L was assessed using receiver operating characteristic (ROC) analysis. The mean difference between the PoC device and the standard laboratory method was −5.6 ​μmol/L, with a 95% confidence interval ( CI ) of −45.1 ​μmol/L to 33.9 ​μmol/L. The coefficient of determination ( R 2 ) was 0.986. The PoC device achieved a detection sensitivity of 90% and specificity of 97% in categorising bilirubin concentrations within bands used in clinical decision-making. This study demonstrates that the proposed PoC device is capable of measuring bilirubin levels in patient samples with clinically acceptable accuracy. • A novel point-of-care device for measuring bilirubin concentrations. • Device uses an optoelectronic sensing module and microfluidic cartridge. • High clinically accuracy coefficient of determination compared to standard method. • Strong diagnostic capabilities, achieving a sensitivity of 90% and specificity of 97%.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A pilot cohort study of a microfluidic-based point-of-care bilirubin measurement system
Date Crossref
01/06/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Neonatal Health and BiochemistryHeme Oxygenase-1 and Carbon MonoxideMethemoglobinemia and Tumor Lysis Syndrome

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.