Cross-field strength and multi-vendor reliability of MagDensity for MRI-based quantitative breast density analysis
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: Breast density (BD) is a significant risk factor for breast cancer, yet current assessment methods lack automation, quantification, and cross-platform consistency. This study aims to evaluate the reliability and cross-platform consistency of MagDensity, a novel magnetic resonance imaging (MRI)-based quantitative BD measure, across different imaging platforms. METHODS: Ten healthy volunteers participated in this prospective study, undergoing fat-water MRI scans on three scanners: 3T Siemens Prisma, 3T Siemens Biograph mMR, and 1.5T GE Signa. Great effort was made to schedule all scans within a narrow three-hour window on the same day to minimize any potential intra- or inter-day variations, requiring substantial logistical coordination. BD was assessed using the MagDensity technique, which included combining magnitude and phase images, applying a fat-water separation technique, employing an automated whole-breast segmentation algorithm, and quantifying the volumetric water fraction. Agreement between measures across scanners was analyzed using mean differences, two-tailed t-tests, Pearson's correlation, and Bland-Altman analysis. RESULTS: MagDensity measures obtained from the two 3T Siemens scanners demonstrated no statistically significant differences, with high correlation (Pearson's r > 0.99) and negligible mean differences (< 0.2%). Cross-platform comparison between the 3T Siemens and the 1.5T GE scanners showed larger mean differences (< 4.2%). However, after applying linear calibration, these variations were reduced to within ±0.2%, with strong inter-scanner correlation maintained (Pearson's r > 0.97). CONCLUSION: MagDensity showed strong intra-vendor consistency and promising cross-platform reliability after leave-one-out calibration. While full standardization remains a long-term goal, these findings provide clear evidence that scanner-related variability can be effectively mitigated through calibration. This technique offers a step further toward more consistent MRI-based BD quantification and may help enable broader clinical implementation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Cross-field strength and multi-vendor reliability of MagDensity for MRI-based quantitative breast density analysis
- Date Crossref
- 24/06/2025
- Éditeur
- Public Library of Science (PLoS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Emory University Department of Radiology and Imaging Sciences pays non établi dans la noticeUniversité ou école supérieure
-
Stony Brook University Department of Biomedical Engineering pays non établi dans la noticeUniversité ou école supérieure
-
Stony Brook School pays non établi dans la noticeUniversité ou école supérieure
-
Georgia Institute of Technology pays non établi dans la noticeUniversité ou école supérieure
Department of Radiology and Imaging Sciences — Emory University, Department of Biomedical Engineering — Stony Brook University et Stony Brook School, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.