Comparative evaluation of an AI-based counting system (OvaCyte™) and the McMaster counting method for quantification of strongyle eggs in sheep faeces

2Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : se, cz. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

We compared an artificial intelligence (AI)-based technology (OvaCyte™, OC) for the enumeration of strongyle eggs in sheep faeces with the McMaster method (MM). Initially, two experiments were performed with faeces containing pure Haemonchus contortus eggs. In experiment A, faeces containing three egg concentrations were processed using OC (extended and standard mode) in parallel with MM. In experiment B, faeces were spiked with different amounts of eggs. Secondly, samples from naturally infected sheep were analysed. Overall, EPG values in experiment A were consistent across all replicates at each dilution. Accuracy was particularly good for the AI-method (mean OC=72 %, mean MM=45 %), and it also achieved the highest precision (CV 5.6-40 %). In experiment B, as in experiment A, within replicate variability was observed at for both methods all concentrations. Although there were no significant differences between sample means, precision and the number of egg-positive samples was higher for OC. Finally, analysis of both experimental (r = 0.98) and field samples (r = 0.93) showed a strong positive correlation between OC and MM. OC also yielded a higher proportion of positive samples than MM in the field study OC provided a higher proportion of positive samples than MM. This study is the first comparison of OC and MM using both experimental and field-based data. In contrast to previous studies, our analysis was based on identical sample preparations that were processed in parallel using both methods. Although the results show strong agreement between methods, some limitations of OC were noted. These limitations can probably be overcome by further refinement of the AI model.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative evaluation of an AI-based counting system (OvaCyte™) and the McMaster counting method for quantification of strongyle eggs in sheep faeces
Date Crossref
01/08/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Helminth infection and controlGenetic and phenotypic traits in livestockMeat and Animal Product Quality

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.