Aller au contenu principal
Accès ouvert déclaré 2025 article

High‐density MRI coil arrays with integrated field monitoring systems for human connectome mapping

3Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : de, us, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

ABSTRACT Purpose To develop and test two high‐density MRI coil arrays with integrated field monitoring systems for enhanced diffusion imaging with strong diffusion‐sensitizing gradients. Methods Two multichannel head coils were constructed for first‐ and second‐generation 3T Connectome MRI scanners, incorporating 64 and 72 receive channels, respectively. The array coils were evaluated using RF bench‐level metrics, including quality factor, tuning, matching, and coupling measurements. Imaging performance was comprehensively assessed through metrics such as SNR, efficiency, and inter‐channel noise correlations, and compared with and without field camera integration. Parallel imaging capability was evaluated using geometry (g)‐factors. The field camera performance was characterized by quantifying phase errors and field probe FID lifetimes. In vivo DWI acquisitions with high ‐values were performed to evaluate the system's ability to correct higher‐order field perturbations. Results The developed arrays demonstrated up to 1.4‐fold higher SNR and superior g‐factor performance when compared to a commercially available 32‐channel head coil. Integration of the field camera was achieved without compromising the performance of either system. In vivo imaging with concurrent field monitoring enabled accurate spatiotemporal field corrections, significantly reducing geometric distortions, blurring, and ghosting in high ‐value DWI. Conclusion The integration of high‐density MRI arrays with field monitoring systems facilitated the capture and correction of spatiotemporal field perturbations during strong gradient activity, substantially enhancing image quality and diffusion parameter mapping quality. These advancements provide a robust platform for exploring the structural intricacies of the human connectome.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
High‐density MRI coil arrays with integrated field monitoring systems for human connectome mapping
Date Crossref
18/06/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMRI in cancer diagnosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.