Megapixel X-ray ghost imaging with a prior-recorded reference
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Introduction Efficient implementation of X-ray ghost imaging (XGI) with megapixel-level field-of-view and spatial resolution of few microns is key towards practical applications of XGI, but such implementation remains constrained by the time-consuming data acquisition and low-quality reconstruction for megapixel images under insufficient overall sampling rates. Methods We propose an efficient implementation scheme based on synthetic aperture X-ray ghost imaging (SAXGI), in which only one set of prior-recorded reference images is needed for ghost imaging of multiple objects. Results Experimental results demonstrated that images of three different objects, including tungsten fiber, resolution chart and small fish, can be successfully reconstructed with the same set of prior-recorded references, which implicates that the efficiency of data acquisition can be improved significantly. Taking advantage of SAXGI, image size of 2040 × 1440 pixels and system resolution of 10 μm was achieved. Results of a small fish show that comparable image quality is achieved with a sampling rate of 27.6%, which means that the radiation dose is reduced to about 1/4 of a conventional radiography. Furthermore, an extreme sampling rate down to 0.5% is enough to make out the skeleton of the fish, which further demonstrates high robustness and the low-dose potential of the proposed method for X-ray imaging. Conclusions In conclusion, the proposed method with a prior-recorded reference is applicable for XGI of multiple samples and the data acquisition efficiency is greatly improved. Through further hardware improvement of the imaging system, SAXGI with a prior-recorded reference is anticipated to provide an efficient solution for megapixel X-ray ghost imaging.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Megapixel X-ray ghost imaging with a prior-recorded reference
- Date Crossref
- 19/06/2025
- Éditeur
- Frontiers Media SA
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.