Optimizing beat-wise input for arrhythmia detection using 1-D convolutional neural networks: A real-world ECG study
Rattachement africain : kr, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUNDS AND OBJECTIVES: Cardiac arrhythmias, characterized by irregular heartbeats, are difficult to diagnose in real-world scenarios. Machine learning has advanced arrhythmia detection; however, the optimal number of heartbeats for precise classification remains understudied. This study addresses this using machine learning while assessing the performance of arrhythmia detection across inter-patient and intra-patient conditions. Furthermore, the performance-resource trade-offs are evaluated for practical deployment in mobile health (mHealth) applications. METHODS: Beat-wise segmentation and resampling techniques were utilized for preprocessing electrocardiography (ECG) signals to ensure consistent input lengths. A 1-D convolutional neural network was used to classify the eight multi-labeled arrhythmias. The dataset comprised real-world ECG recordings from the HiCardi wireless device alongside data from the MIT-BIH Arrhythmia database. Model performance was assessed through fivefold cross-validation under both inter-patient and intra-patient conditions. RESULTS: The proposed model demonstrated peak accuracy at four beats under inter-patient conditions, with minimal improvements beyond this point. This configuration achieved a balance between performance (94.82% accuracy) and resource consumption (training time: 72.27 s per epoch; prediction time: 155 μs per segment). Real-world simulations validated the feasibility of real-time arrhythmia detection for approximately 5000 patients. CONCLUSION: Utilizing four heartbeats as the input size for arrhythmia classification results in a trade-off between accuracy and computational efficiency. This discovery has significant implications for real-time wearable ECG devices, where both performance and resource constraints are crucial considerations. This insight is expected to serve as a valuable reference for enhancing the design and implementation of arrhythmia detection systems for scalable and efficient mHealth applications.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Optimizing beat-wise input for arrhythmia detection using 1-D convolutional neural networks: A real-world ECG study
- Date Crossref
- 01/09/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.