Aller au contenu principal
2025 article

PHYSICAL FACTORS INFLUENCING THE COMPLETENESS OF REMOVAL OF RESIDUAL PERFLUOROCARBON LIQUID IN VITREORETINAL SURGERY

0Citations signalées, ce qui n’est pas une note de qualité
10Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : hk, gb, cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: Postoperative perfluorocarbon liquid (PFCL) retention would lead to serious complications, especially retinal toxicity and intraocular inflammation. This study aimed to elucidate the roles of air infusion pressure and residual balanced salt solution in PFCL evaporation during vitreoretinal surgery, thereby optimizing residual PFCL removal, minimizing complications, and improving patient outcomes. METHODS: Evaporation rates of perfluoro-n-octane and perfluoro-decalin were studied using a 3D-printed eye model under varying air infusion pressures from 10 to 40 mmHg. Computational fluid dynamics simulations were used to qualitatively capture PFCL evaporation dynamics, followed by interpretation with a quantitative mathematical model, which also elucidates the impact of the balanced salt solution film on PFCL evaporation. RESULTS: In the 3D-printed eye model, PFCL completely evaporated at rates of 1.03 µ L/second (perfluoro-n-octane) and 0.28 µ L/second (perfluoro-decalin) at an air pressure of 30 mmHg. Perfluorocarbon liquid evaporation rate increased almost linearly from 10 to 30 mmHg ( P < 0 . 05 ) before reaching its maximum level. Computational fluid dynamics simulations revealed enhanced PFCL evaporation rate as air pressure rises. A mathematical model, based on inlet air pressure enhanced PFCL vapor diffusion, was derived to quantitatively capture PFCL evaporation under clinical conditions with balanced salt solution. CONCLUSION: Both in vitro experiments and mathematical models indicate that trace amounts of PFCL could evaporate completely under surgically representative air pressure levels without significantly extending surgical time. Inlet air pressure significantly accelerates PFCL vapor diffusion rate, dominating PFCL evaporation. The height of the balanced salt solution film exerts a determinant effect on the evaporation of PFCL even under the surgically relevant air infusion pressure level.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
PHYSICAL FACTORS INFLUENCING THE COMPLETENESS OF REMOVAL OF RESIDUAL PERFLUOROCARBON LIQUID IN VITREORETINAL SURGERY
Date Crossref
01/10/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Retinal and Macular SurgeryIntraocular Surgery and LensesGlaucoma and retinal disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.