Tooth-in-eye standardized longitudinal radiological CT monitoring: Clinical impact in a fourteen-year series

0Citations signalées — pas une note de qualité
8Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

PURPOSE: Report the natural history of laminar resorption quantitatively and qualitatively on serial CT after sight-restoring osteo-odonto-keratoprosthesis (OOKP) surgery, conduct OOKP survival analysis, and describe how standardized CT monitoring using a three-prong approach aids clinical evaluation and management, including decision-making for prophylactic OOKP exchange. METHOD: CT data of OOKPs consecutively recruited over a 14-year period since program inception were retrospectively evaluated for laminar resorption on (1) linear measurements, (2) volumetry, (3) cross-sectional imaging and three-dimensional rendering. Findings in relation to ophthalmic complications on clinical follow-up were described, and OOKP Kaplan-Meier survival analysis performed. RESULTS: 40 OOKPs (38 patients, mean age 39.9 years, 22 men) underwent a total of 197 serial CTs (average 3.9 scans per OOKP at 1.4-year intervals over 5.5-year follow-up). They charted a wide time range to first significant CT resorption (4.7 months-10.0 years): median time 3.6 years, and moderate/severe resorption < 5 years in 8/9 (88.9 %) OOKPs. Survival analysis showed steady laminar resorption beyond 2.3 years in Stevens-Johnson syndrome (SJS) patients, compared to less progressive resorption in non-SJS patients. Manual linear measurements were more sensitive than automated volumetry to laminar resorption, especially for the more commonly affected thinner and superior/inferior poles. Moderate/severe resorption culminated in OOKP failure and ocular loss in three patients; two showed preceding telltale peri-optic erosions despite clinical stability. Three other patients underwent prophylactic OOKP exchange to salvage vision. CONCLUSIONS: Lifelong, standardized three-prong CT monitoring for OOKP resorption value-adds to clinical evaluation, assisting decision-making for early intervention to avert irrevocable blindness.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Tooth-in-eye standardized longitudinal radiological CT monitoring: Clinical impact in a fourteen-year series
Date Crossref
01/09/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Corneal Surgery and TreatmentsCorneal surgery and disordersOcular Disorders and Treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.