19-Gauge Versus 22-Gauge Franseen Needles, Comparison of the Histological Diagnostic Capability of Endoscopic Ultrasound-Guided Fine-Needle Biopsy for Autoimmune Pancreatitis: A Multicenter Retrospective Cohort Study
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background/Objectives: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is a useful procedure for obtaining histological specimens. However, its utility in diagnosing autoimmune pancreatitis (AIP) has not yet been well studied. This study aimed to assess the diagnostic capability of EUS-FNB for AIP by comparing a 19-gauge Franseen needle (19FR) and a 22-gauge Franseen needle (22FR). Methods: This study included patients with a final diagnosis of AIP undergoing EUS-FNB for pancreatic lesions between January 2014 and February 2023. All patients underwent EUS-FNB with either 19FR or 22FR. Histological findings were evaluated according to the International Consensus Diagnostic Criteria (ICDC). The primary outcome was the diagnostic yield of Level 1 (≥3 ICDC items) or Level 2 (2 ICDC items). Results: The 19FR group included 31 patients, and the 22FR group included 36 patients. The Level 1 diagnostic rate was significantly higher in the 19FR group than in the 22FR group (90.3% vs. 61.1%, p = 0.010). No significant difference was observed in the Level 2 diagnostic rate. The 19FR group yielded significantly larger histological tissue samples than the 22FR group (median area: 9.19 mm2/session vs. 3.36 mm2/session, p < 0.001). The analysis demonstrated a positive correlation between tissue area and the number of histological diagnostic items obtained. Conclusions: EUS-FNB performed with the 19FR provided larger histological specimens and a higher histological diagnostic yield than the 22FR in the diagnosis of AIP. Obtaining a larger amount of tissue may facilitate a definitive diagnosis of AIP.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 19-Gauge Versus 22-Gauge Franseen Needles, Comparison of the Histological Diagnostic Capability of Endoscopic Ultrasound-Guided Fine-Needle Biopsy for Autoimmune Pancreatitis: A Multicenter Retrospective Cohort Study
- Date Crossref
- 12/06/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.