Aller au contenu principal
Accès ouvert déclaré 2025 article

Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net

6Citations signalées — pas une note de qualité
11Institutions déclarées
5Pays d’affiliation déclarés

Résumé fourni par la source

Background Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation; a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution ECG-triggered free-breathing respiratory motion-corrected 3D bright- and black-blood MRA images. Methods Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 black-blood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with nnU-Net for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% training: validation: testing split. Inference was run on datasets (single vendor) from different centres (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared CMRA, and TWIST MRA), acquired resolutions (from 0.9 mm 3 to 3 mm 3 ), and field strengths (0.55T, 1.5T, and 3T). Predictive measurements comprised Dice Similarity Coefficient (DSC), and Intersection over Union (IoU). Postprocessing (3D slicer) included centreline extraction, diameter measurement, and curved planar reformatting (CPR). Results The optimal configuration was the 3D U-Net. Bright blood segmentation at 1.5T on iT2PrepIR-BOOST datasets (1.3 and 1.8 mm 3 ) and 3D CMRA datasets (0.9 mm 3 ) resulted in DSC ≥ 0.96 and IoU ≥ 0.92. For bright-blood segmentation on 3D CMRA at 0.55T, the nnUNet achieved DSC and IoU scores of 0.93 and 0.88 at 1.5 mm³, and 0.68 and 0.52 at 3.0 mm³, respectively. DSC and IoU scores of 0.89 and 0.82 were obtained for CMRA image sets (1 mm 3 ) at 1.5T (Barcelona dataset). DSC and IoU score of the BRnnUNet model were 0.90 and 0.82 respectively for the contrast-enhanced dataset (TWIST MRA). Lumen segmentation on black blood 1.5T iT2PrepIR-BOOST image sets achieved DSC ≥ 0.95 and IoU ≥ 0.90, and vessel wall segmentation resulted in DSC ≥ 0.80 and IoU ≥ 0.67. Automated centreline tracking, diameter measurement and CPR were successfully implemented in all subjects. Conclusion Automated aortic lumen and wall segmentation on 3D bright- and black-blood image sets demonstrated excellent agreement with ground truth. This technique demonstrates a fast and comprehensive assessment of aortic morphology with great potential for future clinical application in various cardiovascular diseases.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net
Date Crossref
01/01/2025
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Aortic Disease and Treatment ApproachesMedical Image Segmentation TechniquesCoronary Interventions and Diagnostics

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.