Aller au contenu principal
Accès ouvert déclaré 2025 article

The electroencephalography protocol for the Accelerating Medicines Partnership® Schizophrenia Program: Reliability and stability of measures

8Citations signalées — pas une note de qualité
73Institutions déclarées
14Pays d’affiliation déclarés

Résumé fourni par la source

Individuals at clinical high risk for psychosis (CHR) have variable clinical outcomes and low conversion rates, limiting development of novel and personalized treatments. Moreover, given risks of antipsychotic drugs, safer effective medications for CHR individuals are needed. The Accelerating Medicines Partnership® Schizophrenia (AMP® SCZ) Program was launched to address this need. Based on past CHR and schizophrenia studies, AMP SCZ assessed electroencephalography (EEG)-based event-related potential (ERP), event-related oscillation (ERO), and resting EEG power spectral density (PSD) measures, including mismatch negativity (MMN), auditory and visual P300 to target (P3b) and novel (P3a) stimuli, 40-Hz auditory steady state response, and resting EEG PSD for traditional frequency bands (eyes open/closed). Here, in an interim analysis of AMP SCZ EEG measures, we assess test-retest reliability and stability over sessions (baseline, month-2 follow-up) in CHR (n = 654) and community control (CON; n = 87) participants. Reliability was calculated as Generalizability (G)-coefficients, and changes over session were assessed with paired t-tests. G-coefficients were generally good to excellent in both groups (CHR: mean = 0.72, range = 0.49-0.85; CON: mean = 0.71, range = 0.44-0.89). Measure magnitudes significantly (p < 0.001) decreased over session (MMN, auditory and visual target P3b, visual novel P3a, 40-Hz ASSR) and/or over runs within sessions (MMN, auditory/visual novel P3a and target P3b), consistent with habituation effects. Despite these small systematic habituation effects, test-retest reliabilities of the AMP SCZ EEG-based measures are sufficiently strong to support their use in CHR studies as potential predictors of clinical outcomes, markers of illness progression, and/or target engagement or secondary outcome measures in controlled clinical trials.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The electroencephalography protocol for the Accelerating Medicines Partnership® Schizophrenia Program: Reliability and stability of measures
Date Crossref
06/06/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

University of California, San FranciscoSan Francisco VA Health Care SystemNorthern California Institute for Research and EducationBrigham and Women's HospitalHarvard UniversityThe University of MelbourneOrygenUNSW SydneyUniversity of MinnesotaWashington University in St. LouisUniversity of CambridgeUniversity of North Carolina at Chapel HillDepartment of Behavioral Health and Intellectual Disability ServicesYale UniversityNorthwell HealthFeinstein Institute for Medical ResearchDonald & Barbara Zucker School of Medicine at Hofstra/NorthwellUniversity of PaviaUniversity of CopenhagenGlostrup HospitalJena University HospitalTemple UniversityUniversity of LausanneChonnam National UniversityKing's College LondonUniversity of California, IrvineAlberto Hurtado UniversityUniversity of ChileBoston VA Research InstituteIcahn School of Medicine at Mount SinaiLudwig-Maximilians-Universität MünchenInstituto de Salud Carlos IIIHospital General Universitario Gregorio MarañónCentro de Investigación Biomédica en Red de Salud MentalDouglas CollegeMcGill UniversityUniversity of PennsylvaniaUniversity of BirminghamUniversity of PittsburghNorthwestern UniversityBehavioral Health NetworkUniversity of Hong KongUniversity of OregonShanghai Mental Health CenterUniversity of Rochester MedicineThe Ohio State University Wexner Medical CenterUniversity of CologneUniversity Hospital CologneNational University of SingaporeUniversity of CalgaryHotchkiss Brain InstituteKing's College SchoolBirmingham Women’s and Children’s NHS Foundation TrustUniversity of California San DiegoUniversidad del DesarrolloClínica AlemanaOregon Research InstituteBeth Israel Deaconess Medical CenterSeoul National UniversitySeoul National University HospitalHanyang University Seoul HospitalHartford HospitalUniversidad de SalamancaInstituto de Investigación Biomédica de SalamancaCambridgeshire and Peterborough NHS Foundation TrustConnecticut Mental Health CenterUniversity of GeorgiaUniversity of OxfordDuke-NUS Medical SchoolInstitute of Mental HealthÉcole de Technologie SupérieureMassachusetts General HospitalUniversity of California, Los Angeles

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Neural dynamics and brain functionEEG and Brain-Computer InterfacesFunctional Brain Connectivity Studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.