Aller au contenu principal
Accès ouvert déclaré 2025 article

Extreme Heat and Arrhythmia in Patients With Implanted Devices

1Citations signalées — pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Arrhythmia, particularly atrial fibrillation, is on the rise globally. While increased surveillance, aging populations, and other risk factors partially explain this rise, emerging risks such as extreme heat from climate change are underexplored. METHODS: We used Product Surveillance Registry by Medtronic (2016-2023) in the United States to examine patients with implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator devices. We identified first arrhythmic episodes (atrial tachycardia/fibrillation [AT/AF] or ventricular tachycardia/fibrillation) recorded by devices. Events were matched to ambient temperatures from local weather stations. We used a case-crossover design where each arrhythmia event hour was matched with multiple control hours from the same patient, within the same day of week, month, and year. Conditional logistic models were then pooled across all climate zones in the United States to obtain nonlinear dose-response between temperature and arrhythmia. RESULTS: <0.001). We found a significant dose-response relationship between high outdoor temperatures and AT/AF events. Relative to an optimal temperature (19 °C), odds ratios for AT/AF events increased substantially at temperatures of 39 °C (odds ratio, 2.41 [95% CI, 1.37-4.25]), 40 °C (odds ratio, 2.60 [95% CI, 1.38-4.89]), and 41 °C (odds ratio, 2.81 [95% CI, 1.40-5.63]). No significant association between temperature and ventricular tachycardia/ ventricular fibrillation was observed. Lagged temperature exposures did not change the results. CONCLUSIONS: Extreme hot outdoor temperatures were significantly associated with higher odds of AF episodes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Extreme Heat and Arrhythmia in Patients With Implanted Devices
Date Crossref
17/06/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Climate Change and Health ImpactsThermal Regulation in MedicineThermoregulation and physiological responses

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.