Aller au contenu principal
2025 conference-paper

A Deep Learning Model for Breast Shear Wave Elastography to Improve Breast Cancer Diagnosis (INSPiRED 006): An International, Multicenter Analysis

0Citations signalées, ce qui n’est pas une note de qualité
18Institutions déclarées
7Pays d’affiliation déclarés

Rattachement africain : de, us, fr, pt, at, nl, jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Breast shear wave elastography (SWE) has been evaluated to enhance B-mode breast ultrasound performance. Although multi-center trials have shown potential benefits for patients with BI-RADS 4(a) breast masses, its adoption is limited due to the lack of a prospectively validated velocity cutoff for malignancy. This study aims to develop and validate a deep learning (DL) model using SWE images for BI-RADS 3 and 4 breast masses and compare its performance to human experts using B-mode ultrasound. Methods: Data from an international, multicenter trial (NCT02638935) were used to assess SWE's diagnostic performance in women with BI-RADS 3/4 breast masses across 12 institutions in 7 countries. Images from 11 study sites were used to train a DL model with an EfficientNetB1 backbone, and images from the 12 th study site served as an external validation set. Performance metrics included sensitivity and false-positive rates and AUROC. Results: The study included 924 patients (4026 images) for model development and 194 patients (562 images) for external validation. Breast cancer was diagnosed in 29.2% of the development set and 24.2% of the validation set. The SWE DL model achieved an AUROC of 0.94 in the external validation set. Compared to B-mode ultrasound, the SWE DL model significantly reduced the false-positive rate (20.41% vs. 53.81%, 62.07% reduction) with comparable sensitivity (97.9% vs. 98.1%). Conclusion: The SWE-DL model showed equivalent accuracy to human experts in detecting malignancies while significantly reducing unnecessary biopsies. Future studies should evaluate its integration into multi-modal breast cancer diagnostics in a prospective setting. Publication History Article published online: 04 June 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Deep Learning Model for Breast Shear Wave Elastography to Improve Breast Cancer Diagnosis (INSPiRED 006): An International, Multicenter Analysis
Date Crossref
01/06/2025
Éditeur
Georg Thieme Verlag KG
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Infrared Thermography in MedicineAI in cancer detectionUltrasound Imaging and Elastography

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.