Finite element fracture load analysis and dark-field X-ray imaging of osteoporotic and healthy vertebrae in human lumbar spine specimens

3Citations signalées — pas une note de qualité
6Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Purpose This study investigated the association of measurements from a clinical X-ray dark-field prototype system and CT-based finite element analysis (FEA) in lumbar spine specimens. Materials and Methods In this prospective study, human cadaveric spine specimens (L2 to L4) were examined using a clinical prototype for dark-field radiography, yielding both attenuation and dark-field images. Specimens were scanned in vertical and horizontal positions. Volumetric bone mineral density (BMD) values were derived from quantitative CT measurements. Bone segmentation masks derived from CT-images were used for FEA-estimated fracture load (FL) calculations. FEA-estimated FL, dark-field, and attenuation signals were compared between osteoporotic/osteopenic (BMD < 120 mg/cm3) and non-osteoporotic/osteopenic specimens using the paired t-test and the Wilcoxon Mann–Whitney U test. Associations were tested using Spearman correlation. Results Fifty-nine vertebrae from 20 lumbar spine specimens (mean age, 73 years ± 13; 11 women) were studied. FEA-estimated FL correlated with BMD (r = 0.75, p < .001) and was significantly lower in osteoporotic/osteopenic vertebrae (1222 ± 566 vs. 2880 ± 1182, p < .001). Dark-field and attenuation signals were positively correlated with FEA-estimated FL, in both vertical (rdarkfield = 0.64, p < .001, rattenuation = 0.82, p < .001) and horizontal position (rdarkfield = 0.55, p < .001, rattenuation = 0.81, p < .001). Conclusion Dark-field and attenuation signals assessed using a clinical X-ray dark-field system significantly correlated with FEA-estimated FL in human spine specimens with and without osteoporosis/osteopenia. Dark-Field imaging may complement existing assessment methods for bone strength as a dose-efficient, accessible tool.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Finite element fracture load analysis and dark-field X-ray imaging of osteoporotic and healthy vertebrae in human lumbar spine specimens
Date Crossref
03/06/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Bone health and osteoporosis researchMedical Imaging and AnalysisMedical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.