Development of Computational Pipeline for Right Ventricular Hemodynamic Single-Beat Analysis
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Load-independent indices of right ventricular (RV) dysfunction aid in the prognosis of patients with pulmonary hypertension (PH), but their acquisition remains difficult. This study aimed to develop a novel computer vision artificial intelligence-based pipeline that can estimate load-independent RV functional indices using screenshots of the RV pressure-time waveform from a standard clinical right heart catheterization (RHC). Methods: Prospectively collected clinical data and research-grade pressure-volume-time data were collected from 76 patients from three centers. Patients were referred for RHC for known or suspected PH. Thirty-nine patients from one center were used for internal development, with external validation performed on the remaining 37 patients from two independent centers. A MATLAB-based computational pipeline was developed to predict RV pressure-volume (P-V) loop and extract load-independent RV indices using image processing and single-beat analysis. Agreement with gold-standard single-beat analysis was assessed via Bland-Altman analysis, concordance correlation coefficient (CCC), and Pearson correlation coefficient. Kaplan-Meier survival analysis, Cox regression analysis, and K-means clustering were performed to evaluate prognostic value. Results: The average age of the derivation cohort was 57±12 years. Strong concordance was observed between the novel and gold-standard methods for end-systolic elastance (Ees, R=0.96, CCC=0.58), effective arterial elastance (Ea, R=0.97, CCC=0.88), end-diastolic elastance (Eed, R=0.87, CCC=0.47), and Ees/Ea ratio (R=0.93, CCC=0.71). Agreement was validated with the external cohort. Prognostic analyses showed that pipeline-derived Ea (HR: 2.09 [1.04, 4.20]) and Ees/Ea (HR: 0.27 [0.08, 0.87]) were significant predictors of clinical outcomes. Cluster analysis identified two RV sub-phenotypes with distinct hemodynamic features, with the group exhibiting higher Ea (1.05±0.27 vs. 0.41±0.19 mmHg/mL, p<0.0001) and lower Ees/Ea (0.37±0.15 vs. 0.76±0.40 mmHg/mL, p=0.0002) demonstrating worse outcomes. Conclusion: We have developed a novel computational pipeline tool that digitizes and generates single-beat estimates of RV-pulmonary arterial coupling from an image of the RV pressure waveform. Its output correlates with single-beat methods and predicts clinical outcomes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Development of Computational Pipeline for Right Ventricular Hemodynamic Single-Beat Analysis
- Date Crossref
- 02/06/2025
- Éditeur
- openRxiv
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.