Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study
Résumé fourni par la source
BACKGROUND: Obstetric anal sphincter injuries (OASIs) occur during childbirth, affecting up to 11.0% of women. Three-Dimensional High-Resolution Anorectal Manometry (3D-HR-ARM) provides an advanced evaluation of pathophysiological anorectal abnormalities and allows identification of potential lesions. The aim of the study was to evaluate the diagnostic accuracy and inter-rater reliability of (3D-HR-ARM) in identifying OASIs compared to ultrasound assessment. METHODS: A retrospective cohort study was conducted at a tertiary referral center from January 2021 to June 2023. Women with anal incontinence (AI) following a vaginal delivery underwent assessment with both 3D-HR-ARM and endoanal ultrasound (3D-EAUS). Diagnostic accuracy in identifying anal sphincter defects was determined using 3D-EAUS as the gold standard, and inter-rater reliability was assessed among multiple observers. KEY RESULTS: Among 35 women, 19 had OASIs. For identifying severe residual defects (global Starck score ≥ 8), 3D-HR-ARM demonstrated an accuracy of 95.7% (95% CI 79.0-99.2), sensitivity of 100% (95% CI 64.6-100), specificity of 93.8% (95% CI 71.7-98.9), positive predictive value (PPV) of 87.5% (95% CI 52.9-97.8), and negative predictive value of 100% (95% CI 79.6-100). However, its accuracy decreased to 68.6% (95% CI 52.0-81.4) for detecting any sphincter defect. Inter-rater agreement varied from good (κ = 0.60) to mild (κ = 0.27), depending on the observer pair. CONCLUSIONS: 3D-HR-ARM shows potential for the identification of severe OASIs in women with AI symptoms. However, its moderate accuracy for mild defects and significant inter-rater variability underscore the need for standardized protocols and additional training to improve reliability.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study
- Date Crossref
- 02/06/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.