A new esophageal safety paradigm in catheter ablation of atrial fibrillation. Does the Pulsed-field ablation induce an esophageal and periesophageal injury?

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background The newly introduced pulsed field ablation (PFA) is a promising nonthermal, cardiac tissue selective ablation modality for pulmonary vein isolation (PVI). Recently, high acute success rates and good safety features have been reported. Until now no atrio-esophageal fistula related to PFA has been reported. However, this fatal complication is rare and endoscopically detected esophageal lesions (EDEL) may serve as a more sensitive instrument to document esophageal safety. Aim of the study This study sought to evaluate the esophageal safety of the Farapulse PFA system for PVI. Methods In patients with symptomatic atrial fibrillation (AF), Farapulse PFA-system was used for PVI under propofol sedation. Additional left atrial posterior PFA application was performed in some cases. Esophageal endoscopy was performed in all patients within 1 day after ablation. Follow up included two systematic follow up visits 3 and 12 months after the procedure. The patients were asked to have two long-term ECGs performed before each visit. Results The study enrolled 127 consecutive patients with symptomatic AF (74.8 % paroxysmal). The baseline characteristics are shown in Table 1. The patients were relatively young (age 66.27 ± 9.74 years), 34.6 % were of male gender. The mean left ventricular function was normal (60 ± 8 %), and the mean LA diameter was 41 ± 5 mm. In 20 patients (16%) a redo procedure was performed after a former cryoballoon (75%) ablation or RF( 25%). Of them in 11 (55%) no Re-PVI was needed. Altogether, 12 patients (9%) received additional posterior wall ablation. The procedural characteristics are shown in Table 2. All pulmonary veins could be successfully isolated .The procedure time was 65 ± 11 min, fluoroscopy duration 9 ± 3 min, and the median dose area product was 599 ± 441.9 cGy cm2 . Procedural complications included one AV fistula without necessary intervention and two minor hematomas. No stroke, pericardial tamponade or phrenic nerve alteration occurred. In none of the patients EDEL were detected. Follow up results will be finalized until presentation. Conclusions PVI using PFA for atrial fibrillation appears to be a very safe and effective. There is no collateral damage to the phrenic nerve or the oesophagus.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A new esophageal safety paradigm in catheter ablation of atrial fibrillation. Does the Pulsed-field ablation induce an esophageal and periesophageal injury?
Date Crossref
01/05/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsAtrial Fibrillation Management and OutcomesCardiac electrophysiology and arrhythmias

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.