Aller au contenu principal
Accès ouvert déclaré 2025 article

Retrospective observational study of tricuspid regurgitation in patients with device implantation (PM, CRT) in LBBP Position

0Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background Tricuspid regurgitation (TR) is a common complication after device implantation. While conventional right ventricular pacing shows TR progression in 20% of cases (4-7% severe), left bundle branch area pacing's (LBBP) impact remains understudied. Previous studies suggest that shorter distance between septal implant position and tricuspid valve may increase TR risk. Purpose To investigate TR prevalence, mechanisms, and contributing factors in LBBP device implantation patients. Methods Retrospective study of 65 LBBP device implantation patients. Echocardiographic data by two-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (TTE) evaluation, including TR severity, mechanism, the number of leads crossing the tricuspid valve, the distance of the LBBP lead from the left ventricular base, and right ventricular diameter, were collected. Results TR was present in 46 patients (70.76%), predominantly functional due to right ventricular dilation (63.07%). Lead-related mechanisms were less common: lead impingement (4.62%) and subvalvular/leaflet interference (3.08%). Detailed echocardiographic analysis of lead-related TR revealed the following: In three patients, echocardiographic assessment revealed lead impingement of the tricuspid valve leaflets, confirmed by 3D echocardiography. In two patients, lead interference with the subvalvular apparatus was observed. In the first case, the lead was positioned towards the anterior leaflet and became entangled beneath the subvalvular mechanism. In the second case, lead entanglement with the subvalvular apparatus occurred during the implantation procedure, resulting in chordal rupture during attempted lead repositioning, requiring transesophageal echocardiography (TEE) assessment. TR severity distribution: mild (49.23%), moderate (18.46%), mild-to-moderate (3.07%). Lead configurations included single pacing (64.60%), dual leads (21.55%), and pacing plus defibrillator (13.85%), with no significant difference in TR prevalence among configurations (p>0.05). Median LBBP lead distance from left ventricular base was 31mm (IQR: 27-38mm), with median RV diameter of 40mm (IQR: 37-44mm). Implantation indications: conduction disorders (49.23%), dyssynchrony (36.92%), PM upgrade (9.23%), ICD upgrade (1.54%), and AF pace/ablate (3.08%). Devices included DR PPM (55.38%), CRT-P (21.54%), LOT CRT-D (7.69%), CRT-D (6.16%), VR PPM (4.61%), and LOT CRT-P (4.62%). Limitations: Lack of pre-implantation echocardiographic data and direct comparison with conventional RV pacing limits definitive conclusions about LBBP advantages. Additionally, this represents preliminary data from an ongoing study. Conclusion LBBP shows high TR prevalence (70.76%), with functional TR predominating over lead-related mechanisms (7.70%). Lead configuration did not significantly impact TR prevalence, suggesting other factors' importance.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Retrospective observational study of tricuspid regurgitation in patients with device implantation (PM, CRT) in LBBP Position
Date Crossref
01/05/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac pacing and defibrillation studiesCardiac Arrhythmias and TreatmentsTransplantation: Methods and Outcomes

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.