Aller au contenu principal
2025 article

Perioperative Glucose Pragmatic (PROGRAM) Trial: Standardized Insulin Management in Surgical Patients

1Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Perioperative hyperglycemia is associated with adverse patient outcomes including surgical site infections. This study examined whether an automated insulin dosing reminder is associated with a lower risk for postoperative hyperglycemia and other secondary and safety outcomes in patients at high risk for intraoperative hyperglycemia. METHODS: The authors conducted a pragmatic trial using a sequential and repeated crossover design between October 5, 2022, and October 26, 2023. They sequentially assigned anesthesia providers to receive either an automated insulin dosing reminder (intervention) or a glucose check reminder (routine care) periodically throughout surgery for a consecutive sample of adult patients at high risk for intraoperative hyperglycemia undergoing major surgery at their quaternary medical center. The primary outcome was hyperglycemia (glucose greater than 180 mg/dl) at the first postoperative measurement 3 h or less postoperatively. The primary analysis studied the association between automated insulin dosing reminder and postoperative hyperglycemia adjusted for demographics, surgery characteristics, preoperative glucose, time period, and the interaction of intervention and time period. RESULTS: A total of 4,558 cases qualified for primary analysis: 2,611 cases in the routine care group and 1,947 cases in the intervention group. A total of 970 (37%) and 675 (35%) cases, respectively, experienced the primary outcome. The authors found no evidence of an association between treatment and postoperative hyperglycemia in the overall study period (odds ratio [OR], 0.90; 95% CI, 0.78 to 1.03; P = 0.165). There was no evidence of difference in intraoperative glucose monitoring (OR, 0.99; 95% CI, 0.83 to 1.19; P = 0.369) and intraoperative insulin use (OR, 1.00; 95% CI, 0.83 to 1.20; P = 0.995). The odds of surgical site infections were higher in the intervention group (overall unadjusted OR, 2.52; 95% CI, 1.37 to 4.64; P = 0.006). No difference in safety endpoints was observed between groups. CONCLUSIONS: Among surgical patients at high risk of intraoperative hyperglycemia, an automated insulin dosing reminder did not improve glycemic control or other outcomes compared with a glucose check reminder.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Perioperative Glucose Pragmatic (PROGRAM) Trial: Standardized Insulin Management in Surgical Patients
Date Crossref
23/05/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Hyperglycemia and glycemic control in critically ill and hospitalized patientsEnhanced Recovery After SurgeryDiabetes Management and Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.