Left bundle branch area pacing: longitudinal data on pacing efficacy
Rattachement africain : pt. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Left bundle branch area pacing (LBBAP) has gained recognition as a technique for physiological ventricular pacing that maintains left ventricular (LV) synchrony. Although procedural characteristics are increasingly documented, information on longer terms lead stability remains scarce. We aimed to evaluate the procedural features and the stability of pacing parameters over a mid-term follow-up. Methods Single centre study including consecutive patients undergoing LBBAP from 2021 to 2024. Data on procedural characteristics, lead parameters, and final QRS duration were gathered immediately post-implantation and throughout follow-up. Criteria for confirming conduction system capture with LBBAP was defined according to current recommendations. Results Overall, 205 consecutive patients were included (mean age 77±12 years and 64% male). Procedural duration was 63min (IQR 51-80) and fluoroscopy time was 4.9min (IQR 2.9-7.8). Median LVAT was 86ms (IQR 78-96), paced QRS immediately after implantation was 112ms (IQR 104-120) and interpeak V1-V6 was 38ms (30-44). Acute R-wave amplitude and pacing threshold were 11.4 mV (IQR 6.9-15.7) and 0.5 mV (IQR 0.5-0.7), respectively. One case of in-hospital ischemic stroke associated with withholding anticoagulation in a patient with atrial fibrillation and 1 case of electrode dislocation with successful replacement were reported at discharge. No other major complications were reported. Over a median follow-up of 7.9 months (IQR 2.3-15.3), both the pacing threshold (0.6 mV [IQR 0.5-0.75]) and R-wave amplitude [12.3 mV (IQR 9.0-19.3)] remained stable. QRS duration, a surrogate of LV synchrony, remained narrow: 120ms (IQR 110-122). Conclusion In this cohort, LBBAP proved feasible, demonstrating excellent pacing parameters that remained stable throughout the mid-term follow-up. QRS duration remained consistently short, further underscoring the potential of this technique in maintaining LV synchrony.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Left bundle branch area pacing: longitudinal data on pacing efficacy
- Date Crossref
- 01/05/2025
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.