Aller au contenu principal
Accès ouvert déclaré 2025 conference-abstract

Eddy covariance measurements of CO2 fluxes along an urban-to-rural gradient in the Paris area

0Citations signalées, ce qui n’est pas une note de qualité
10Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : fr, Tunisie, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Cities are one of the main sources of greenhouse gases, accounting for over 70% of global CO2 emissions. Accurate quantification of these emissions through direct observations is crucial for assessing the effectiveness of adopted mitigation strategies.As part of the European project ICOS Cities (https://www.icos-cp.eu/projects/icos-cities), three eddy covariance towers were installed in the Paris area to capture the variability of surface-atmosphere CO2 fluxes as a function of an urbanization gradient. Specifically, the selected sites were chosen to be representative of a highly urbanised area (Jussieu), an urban forest (Vincennes), and a heterogeneous area combining densely urbanised and vegetated zones (Romainville). The atmosphere ICOS Saclay tower was also equipped with an eddy covariance system to provide a sub-urban environment. Additionally, the observations from the urban sites were integrated with the EC flux measurements from the ecosystem sites of Fontainebleau (FR-FON, forest) and Grignon (FR-GRI, crop). The measurements span 2 years for Romainville and Jussieu and 1 year for Vincennes and Saclay.CO2 flux measurements showed seasonal dynamics that reflected the respective degrees of urbanisation of the sites and the presence of biogenic sinks. Jussieu, in the city centre, was dominated by anthropogenic CO2 emissions, with maximum mean daily emission (up to 15 µmol m-2s-1) during winter months (November-February) and low daytime absorptions (down to -2.5 µmol m-2s-1) in summer (July-August). The mixed urban forest of Vincennes showed a diverse flux pattern with strong biogenic signature, characterized by a predominant CO2 absorption in the central hours of the day (down to -10 µmol m-2s-1 in May, June and July). The 100m-tall tower of Romainville showed instead the coexistence of anthropogenic and biogenic fluxes, each contributing its own seasonal and daily variations to the measured flux. A comparison between our observations and the emissions estimates of the city of Paris will be included in the presentation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Eddy covariance measurements of CO2 fluxes along an urban-to-rural gradient in the Paris area
Date Crossref
21/05/2025
Éditeur
Copernicus GmbH
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atmospheric and Environmental Gas DynamicsWind and Air Flow StudiesHydrocarbon exploration and reservoir analysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.