Aller au contenu principal
Accès ouvert déclaré 2025 article

Can bioelectrical impedance analysis be used to identify water loading in patients with anorexia nervosa?– Implications from experimental measurements in young, healthy, and normal weight women

2Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Anorexia nervosa (AN) is a severe mental disorder, and patients with AN are characterized by a low body weight and a fear of gaining weight. Restoration of body weight to the normal range is one major treatment aim, which can be a challenging process for the patients. Hence, as a psychopathological symptom of AN, weight manipulations such as water loading before weighing are commonly observed in clinical routine. Biological impedance analysis (BIA) is a helpful tool in routinely visualizing changes in body composition during the refeeding process. Here, we targeted the question whether BIA could potentially detect water loading in healthy, young and normal weight women serving as a preclinical model for patients with AN. Sixty-one women (mean ± SD, 22.2 ± 2.2 years, 20.4 ± 1.0 kg/m2) were included in the analyses. We used a full experimental setting with a cross-over design on two consecutive days. On both days, all participants underwent a baseline BIA in the fasting state (t0). Directly thereafter, participants either consumed 1000 ml of tap water (intervention-condition) or waited for the second BIA measurement 20 min (t1) after baseline (control-condition), and vice versa the subsequent day. Two further BIA measurements took place at 40 (t2) and 60 min (t3) after baseline. After water consumption, we found increases in derived fat mass (FM) and phase angle at t1 to t3, decreases at t1 and subsequent increases at t2 and t3 in extracellular water (ECW) and total body water (TBW). In contrast, skeletal muscle mass (SMM) and ECW/TBW remained rather stable. In the control-condition, most parameters remained constant. Our study provided insight into the changes of impedance raw data and derived body compartments after water consumption among young, healthy and normal weight women. Although the considerable increase of FM in combination with a rather stable course of SMM, as found in our experiment after the consumption of water, could be a potential hint for water loading, further investigation considering the limitations of the present study as for instance the different metabolisms of patients with AN vs. healthy women is required, before transferability to the clinical setting will be given.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Can bioelectrical impedance analysis be used to identify water loading in patients with anorexia nervosa?– Implications from experimental measurements in young, healthy, and normal weight women
Date Crossref
19/05/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Essen University Hospital pays non établi dans la notice
    Organisme public
  • University of Duisburg-Essen Center for Translational Neuro- and Behavioral Sciences (C-TNBS) pays non établi dans la notice
    Université ou école supérieure
  • Paderborn University pays non établi dans la notice
    Université ou école supérieure
  • Faculty of Natural Sciences pays non établi dans la notice
    Université ou école supérieure

Essen University Hospital, Center for Translational Neuro- and Behavioral Sciences (C-TNBS) — University of Duisburg-Essen et Paderborn University, avec 1 autre affiliation.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Body Composition Measurement TechniquesThermoregulation and physiological responsesInfrared Thermography in Medicine

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.