Aller au contenu principal
Accès ouvert déclaré 2025 article

Standing transthoracic echocardiography: a feasibility study

1Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background Orthostatic hypotension (OH) is associated with cardiovascular disease, particularly among older adults. While a standing transthoracic echocardiogram (TTE) could theoretically identify changes in cardiac output to diagnose cardiogenic OH, there are no established protocols for orthostatic TTEs and their feasibility is unknown. Methods and results We recruited 115 patients scheduled for elective outpatient TTE. Consenting participants, who were able to stand safely, underwent their scheduled recumbent TTE, followed by a standing TTE, performed within 1–2 minutes of standing. The focused TTE used the apical window to measure velocity time integral across the aortic valve to assess cardiac output. Blood pressure (BP) was measured in the supine and standing positions and patients were asked about symptoms of dizziness and lightheadedness. OH was defined as a change in standing minus supine systolic BP ≤-20 mm Hg or in diastolic BP of ≤-10 mm Hg. Of the 115 enrolled participants, 102 (89%) completed the standing echocardiogram protocol. Among those completing, mean age was 63.4 (SD, 14.8) years (38% were ≥ 70 years), 48% women, and 34% had a BMI ≥ 30 kg/m2. There were 21% with OH. Upon standing, systolic BP changed by -5.9 mm Hg (95% CI: -9.5, -2.2), diastolic BP by 2.4 mm Hg (-0.1, 4.8), and cardiac output by -0.4 L/min (95% CI: -0.7, -0.1). Change in cardiac output (per 1 L/min) was associated with a higher odds of systolic OH (OR: 1.60; 95% CI: 1.05, 2.42), but not diastolic OH (OR: 1.21; 95% CI: 0.63, 2.32). Conclusions Standing TTE is safe, well-tolerated, and feasible in the ambulatory setting. Moreover, TTE changes in cardiac output are associated with systolic OH. This clinical assessment shows promise for distinguishing OH etiologies and could inform further research on treatments to prevent OH.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Standing transthoracic echocardiography: a feasibility study
Date Crossref
20/05/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiovascular Syncope and Autonomic DisordersHemodynamic Monitoring and TherapyHeart Rate Variability and Autonomic Control

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.