Aller au contenu principal
2025 article

Validation of Drum Tower Severity Scoring ( DTSS ) System for Pyrrolizidine Alkaloid‐Induced Hepatic Sinusoidal Obstruction Syndrome

1Citations signalées — pas une note de qualité
12Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVES: The Drum Tower Severity Scoring (DTSS) system is a novel tool designed for assessing the outcome of anticoagulation therapy and disease severity in patients with pyrrolizidine alkaloid-induced hepatic sinusoidal obstruction syndrome (PA-HSOS). The aim of this study was to validate the predictive performance of the DTSS system in PA-HSOS patient outcome. METHODS: We conducted a retrospective analysis of 111 PA-HSOS patients who received standard anticoagulation-transjugular intrahepatic portosystemic shunt (TIPS) stepwise therapy from six hospitals in China. Patients were categorized into two groups based on whether they responded to anticoagulation therapy. The predictive performance of the DTSS system was evaluated through the efficacy of anticoagulation therapy, the area under the receiver operating characteristic curve (AUROC), calibration curve, decision curve analysis (DCA), and clinical impact curve (CIC) analysis. RESULTS: The response rates to anticoagulation therapy varied among patients with DTSS of different severity, being 94.12% for mild, 57.81% for moderate, and 13.33% for severe cases. The DTSS system demonstrated a robust predictive performance, with an AUROC of 0.864. The calibration curve indicated a close match between the predicted and observed effects of the DTSS system. Good calibration was confirmed by the Hosmer-Lemeshow test (p = 0.704), and both the DCA and CIC analysis indicated high clinical utility of the DTSS system. CONCLUSION: The DTSS system is a practical tool that uses easily accessible data to predict the initial response to anticoagulation therapy in PA-HSOS patients, showing robust predictive performance and significant clinical benefit in guiding personalized management strategies.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Validation of Drum Tower Severity Scoring (<scp>DTSS</scp>) System for Pyrrolizidine Alkaloid‐Induced Hepatic Sinusoidal Obstruction Syndrome
Date Crossref
01/03/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Plant Toxicity and Pharmacological PropertiesHematopoietic Stem Cell TransplantationPlant-based Medicinal Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.